User Manual Part 3
Page 3-65
16 Sep 2015
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
FMA (04) Operational
information (FA)
0x 0000 Mode transition Info events - Recording what happened
in the LRU
0x 0001 Parameter
0x 0002 Event
0x 000A Standard electronic
information
0x 000B Honeywell electronic
information
0x 000C Subassembly
information
IP security (FB) 0x 0000 IP security event
Reset (FC) 0x 0000 Power cycle
0x 0001 Watchdog
0x 0002 Software command
0x 0004 SW exception
Software
configuration (FD)
0x 0001 HW SW Compatibility Reload compatible software with the
A615A data loading process.
0x 0002 LRU SW Compatibility
0x 0003 Configuration
parameter missing
Reload the configuration data with the
A615A data loading process.
0x 0004 Primary image
corruption warning
- Reboot the LRU to load valid primary
image and check if fault goes away.
- If not, then a fresh data load of software
is required to load the fresh image.
0x 0005 No Valid Image Reload software with the A615A data
loading process.
0x 0006 LRU PRI-SEC image
mismatch
- Reboot the LRU to load valid primary
image and check if fault goes away.
- If not, then a fresh data load of software
is required to load the fresh image.
0x 0007 Data load Unit configuration events:
- Critical, something needs to be done
(reload software).
- Warning, then the event was
unexpected, but will sort itself out.
- Info, recording what happened in the
LRU.
0x 0008 Data loader connect
0x 0009 Data loader disconnect
0x 000A Operating image list
0x 000B Secondary image
corruption warning
A fresh data load of software is required
to load the fresh image.
Table 3-20. L3 Codes (Cont)
L1 L2 L3 Code L3 Description Repair Action