User Manual Part 3

Page 3-64
16 Sep 2015
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
FMA (04) MDU (0B) 0x 0004 12V positive voltage Hardware faults and events:
- Replace the FMA.
0x 0005 12V negative voltage
0x 0006 38.5V voltage
0x 0007 1.5V current
0x 0008 3.3V current
0x 0009 12V positive current
0x 000A 12V negative current
0x 000B Serial communications
failure
0x 000C Azimuth motor current
0x 000D Elevation motor current
0x 000E Serial communications
failure
0x 000F CCA initialization failed
0x 0010 Azimuth axis low
temperature high
current
R2D (0C) 0x 0001 1.5V voltage
0x 0002 3.3V voltage
0x 0003 5V digital voltage
0x 0004 5V positive voltage
0x 0005 5V negative voltage
0x 0006 12V positive voltage
0x 0007 12V negative voltage
0x 0008 1.5V current
0x 0009 3.3V current
0x 000A 12V positive current
0x 000B 12V negative current
0x 000F Serial communications
failure
0x 0010 CCA initialization failed
0x 0011 Azimuth axis resolver
reading error
0x 0012 Elevation axis resolver
reading error
Table 3-20. L3 Codes (Cont)
L1 L2 L3 Code L3 Description Repair Action