User Manual Part 3
Page 3-59
16 Sep 2015
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
KRFU (02) Unknown (00) 0x 0000 Mute state Info events - Recording what happened
in the LRU.
0x 0001 Primary power
interruption
Power supply (01) 0x 0002 Power supply internal
fault
Hardware faults and events:
- Replace the KRFU
Block up converter
(02)
0x 0001 BUC lockloss: Transmit
BITE status
0x 0002 BUC lockloss: Transmit
BITE status
Power amplifier
(04)
0x 0002 PA overdriven: Transmit
BITE status
Monitor and
control (05)
0x 0001 Flash fault
0x 0002 RAM fault
0x 0003 Watchdog reset
Fan (07) 0x 0000 Fan
Failed on startup
(08)
0x 0000 Failed on startup
BDC (2A) 0x 0001 BDC lockloss: Receive
BITE status
Operational
information (FA)
0x 000A Standard electronic
information
Info events - Recording what happened
in the LRU.
0x 000B Honeywell electronic
information
Reset (FC) 0x 0001 Watchdog
0x 0002 Software command
0x 0004 SW exception
0x 0005 Power cycle or Reset
pin
Software
configuration (FD)
0x 0001 HW SW compatibility Reload compatible software with the
A615A data loading process.
0x 0004 Primary image
corruption warning
- Reboot the LRU to load valid primary
image and check if fault goes away.
- If not, then a fresh data load of software
is required to load the fresh image
0x 0005 No valid image Reload compatible software with the
A615A data loading process.
Table 3-20. L3 Codes (Cont)
L1 L2 L3 Code L3 Description Repair Action