User Manual Part 3
Page 3-55
16 Sep 2015
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
System (00) Regulatory Log
(07)
0x 0000 Regulatory log upload
failure
NO ACTION –System will continue to try
and upload the file as directed by the
regulatory log requirements on frequency
of upload attempts.
0x 0001 Reg log full
0x 0002 FTP address invalid NO ACTION - These are warnings
0x 0003 FTP connection refused
0x 0004 FTP records
misalignment
- Info events - Recording what happened
in the LRU.
Information
Events (08)
0x 0000 User service enabled NO ACTION: - This is AES Information
Event
0x 0001 User service disabled NO ACTION: - Will recover next time
0x 0002 Geographic map stored - Info events - Recording what happened
in the LRU.
0x 0003 Geographic map
received corrupted
NO ACTION: - Will recover next time
Modman (01) Unknown (00) 0x 0000 Mute state Info events - Recording what happened
in the LRU.
0x 0011 LRU menu access -
maintenance
0x 0012 LRU menu access -
factory
0x 0013 LRU menu access -
engineering
0x 0014 LRU SFTP access -
maintenance
0x 0015 LRU SFTP access -
factory
0x 0016 LRU SFTP access -
engineering
0x 0021 Log clearance LRU
operational
0x 0022 Log clearance LRU fault
ACM (01) 0x 0001 ACM not responding Hardware faults and events:
- Replace the Modman.
0x 0002 ACM BIST fault
0x 0003 ACM over temp
Controller/router
(02)
0x 0001 DSP Fault
0x 0002 Ethernet Main Switch
0x 0003 Ethernet PODD Switch
Table 3-20. L3 Codes (Cont)
L1 L2 L3 Code L3 Description Repair Action