User Manual Part 3
Page 3-51
16 Sep 2015
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
(3) The event L2 code further identifies ARINC 429 and ARINC 791 discrete interfaces, coded
as follows:
KANDU OAE Serial IMU Bus (32) 0x 01 KANDU input
0x 02 OAE input
KANDU KRFU Serial Bus (33) 0x 01 KANDU input
0x 02 KRFU input
KANDU Input: Discrete from OAE
(34)
0x 01 FMA TX mute input
KANDU Input: Discrete from Modman
(35)
0x 01 Reset
0x 02 ARINC TX mute
0x 03 Filter select
0x 04 TX Mute
KANDU Input: Discrete from KRFU
(36)
0x 00 Unknown
KRFU Input: Discrete from KANDU
(41)
0x 01 Reset
0x 02 KRFU TX mute
0x 03 Filter select
RF TX Modman to KRFU (B0) 0x 00 Unknown
RF TX KRFU to OAE (B1) 0x 00 Unknown
RF RX(B2) 0x 00 Unknown
Table 3-18. L2 Codes – ARINC Discrete Interfaces
L1 L2 Code L2 Description
IRU Input Bus (70)
Aircraft state Bus (71)
0x 00 Unknown
0x 01 Pitch angle label
0x 02 Roll angle label
0x 03 Pitch rate label
0x 04 Roll rate label
0x 05 Yaw rate label
0x 06 Body longitudinal acceleration
0x 07 Body vertical acceleration
0x 08 True heading label
Table 3-17. L2 Codes – Inter LRU Interfaces (Cont)
L1 L2 Code L2 Description