With the LAIM, the radome will be installed on the Radome skirt fairing assembly. Refer to
the and Figure 2-20.
Figure 2-20. Radome Assembly Mounted on Radome Skirt Fairing (LAIM)
O. FMA Alignment
On completion of physical installation of the
FMA, the installed antenna system has to be aligned
and calibrated for any possible installation offsets. The antenna alignment for the JetWave™
system is designed to be performed automatically once initialized through a GUI interface.
It is recommended to do the antenna alignment calibration after initial installation and whenever the
OAE-FMA is removed and replaced. Only qualified avionics personnel who are knowledgeable in
the technical and safety issues related to the antenna systems should do the alignment procedures
provided in this SDIMM.
Refer to Section 4.Q. TMA and FMA Antenna Alignment Procedure.
P. FMA Human Exposure to RF EM Fields
WARNING: THE JETWAVE™ SYSTEM IS A SOURCE OF NON-IONIZING RADIATION.
(1) The Minimum Safe Distance:
FMA = 66.6 feet (20.3 m).
NOTE: The minimum safe distance for occupational/controlled exposure is determined
based on the computational method specified in FCC Office of Engineering and
Technology; Bulletin Number 65, Edition 97-01: Evaluating compliance with FCC
Guidelines for hum
an exposure to Radio Frequency Electromagnetic fields.