User Manual Part 1

Page 2-10
16 Sep 2015
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
(d) Apply tacky side of thermal pad to the bottom side of unit as shown in Figure 2-1.
1 Making sure to keep a setback dimension of 0.032 to 0.125 inch (0.79 to 3.18 mm)
around the edges of the installed thermal pad.
(e) Remove the clear protective backing to expose the tacky side of thermal pad PN
MPW0000122.
(f) Apply the pad flush to the interior edge of the thermal pad PN MPW0000118, in order to
maintain consistent setback dimension
of 0.032 to 0.125 inch (0.79 to 3.18 mm) around
the edges of the installed thermal pad.
NOTE: The configuration of the mounting feet shown in Figure 2-1 is representative only and may not be
the exact configuration for all KRFUs.
Figure 2-1. KRFU Thermal Pads
CAUTION: THE THERMAL PAD OPAQUE PROTECTIVE BACKING MUST BE
REMOVED FROM BOTH THERMAL PADS BEFORE USE IN THE FINAL
APPLICATION. FAILURE TO DO SO CAN RESULT IN PREMATURE
SHUTDOWN OF THE KRFU DUE TO OVERHEATING.
(g) Immediately before installing the KRFU into the aircraft, remove white opaque protective
backing on both pads to expose t
he non-tacky side of the thermal pad.
NOTE: If the KRFU unit is to be shipped or stored before installation, do NOT remove
the white opaque backing on the thermal pads.
G. Deleted
H. Deleted
I. Tail Mount Antenna