(c) At the time of manufacturing of Modman, the serial numbers of the Modman and
associated DIDs of the ACM are communicated to the Inmarsat service provider as part
of pre-provisioning.
(d) The Modman and associated DIDs of the ACM also allocated a specific SSPP. This
SSPP is required to verify the terminal connectivity to the NMS.
(
9) When commissioning a terminal, a VAR has to assign a service plan to
the subscriber which
becomes effective by associating an SSPP to the JetWave™ AES system.
4. JetWave™ System LRU Installation
This section includes information about installing the equipment in the core JetWave™ system. Contact
Honeywell about installation kits that include mating connectors and cables.
Honeywell recommends that LRUs be installed in accessible locations that are compatible with the
environmental levels that the equipment is certified to handle.
Refer to APPENDIX D for the installation reference checklist.
A. Maintenance Panel
If the JetWave™ system is not wired to other systems on the aircraf
t, the discrete I/O and Ethernet
ports must be brought out to a suitable panel to allow for system checks and routine maintenance,
such as system software upgrades. The discrete I/O and Ethernet ports that are needed are as
follows:
(1) Discrete Outputs:
System available (Modman MP13E) connected to a lamp
Data link available (Modman MP13F) connected to a lamp.
(2) Discrete Inputs:
Local data load enable (Modman MP10B) connected to a normally open switch
Ground transmit enable (Modman MP11D) conn
ected to a normally open
switch
Public service disable (Modman MP11E) connected to a normally open switch
Modman reset (Modman MP10C) connected to a normally open switch.
(3) Ethernet Port:
AV1 (Modman TP BB1 thru 4) connected to a RJ45 Ethernet connector
NOTE: The AVI is the default data loading port, any other Ethernet ports can be selected as
long as the APM configuration file is configured to allow that port to data load.
For LRU pin details, refer to the applicable system interconnect diagram, Figure 2-33 thru
Figure 2-36.
B.
Modman