User Manual Part 1
Page 1-6
16 Sep 2015
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
Interfaces J1 - Aircraft power input
J2 - Control interface from KANDU
J3 - RF TX to OAE
J4 - RF RX from OAE
J5 - IF TX from Modman
J6 - IF RX to Modman
Table 1-6. TMA Leading Particulars
Characteristic Specification
Length 13.38 inches (339.9 mm) maximum
Width 12.00 inches (304.8 mm), maximum reflector sweep volume
Height 13.57 inches (344.7 mm) maximum
Weight 10 pounds (4.55 kg)
Operating voltage 38.5 VDC and 24 VDC for IMU supplied by the KANDU
Power consumption 85 watts at maximum output power
Cooling Natural convection and radiation only
Operating temperature -67°F (-55°C) to 158°F (70°C)
Maintenance No scheduled maintenance required
Interfaces J2 - Power/control interface from KANDU
J3 - RF TX from KRFU
J4 - RF RX to KRFU
Table 1-7. FMA Leading Particulars
Characteristic Specification
Length 23.03 inches (585 mm) maximum
Width 35.72 inches (907.3 mm), maximum reflector sweep volume
Height 9.40 inches (238.8 mm) maximum
Weight 83 pounds (37.6 kg) maximum
NOTE: The lifting fixture is 5.5 pounds (2.5 kg)
Operating voltage 38 VDC and 24 VDC for IMU supplied by the KANDU
Power consumption 160 watts maximum
Table 1-5. KRFU Leading Particulars(Cont)
Characteristic Specification