Page 5-1
28 Feb 2018
23-15-45
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
Aspire-200
© Honeywell International Inc. Do not copy without express permission of Honeywell.
SYSTEM SETUP
1. Setting up Operational Parameters
After the Aspire-200 is installed in the aircraft, you must configure fundamental parameters in order to operate
the system:
• Cable losses
• LES IDs
• The APN
• Navigational input to the system.
A. Connecting to the Aspire-200 Maintenance Port
You can connect to the Aspire-200 through the maintenance port.
T
o connect to the maintenance port:
1. Connect your computer to
the front-panel maintenance port with the
maintenance cable, PN 1541-F-3150, provided in the shipping kit.
2. Start a HyperTerminal session on an active COM port with the following
parameters:
3. Type the password maint.
Th
e password does not appear on screen.
Menu 1 a
ppears when you connect.
B. Configuring Cable Loss
The signal loss in cables between the IPLD and the antenna affect the power
required to access Inmarsat services.
After you install the system, measure the
cable loss and configure the IPLD-to-antenna cable loss parameter.
Parameter Value
Bits per second 19200
Data bits 8
Parity None
Stop bits 1
Flow control None