When installing the Aspire-200, follow the cabling requirements listed below:
The maximum recommended length for USB data connections is 16 feet.
The maximum recommended length for USB power connections is 30 feet.
Ethernet LAN/WAN and ISDN cables must meet flammability and TIA/EIA568-A CAT 5E requirements.
USB cables must meet flammability requirements.
Twisted shielded pairs must meet ARINC 741 wiring requirements or equivalent.
Wire size recommendations for the HDU:
For +28 VDC HOT (BP2), +28 VDC RTN GND (BP3), and Chassis GND (BP8),
use 16 AWG
Unless otherwise specified, for signaling, use 22 AWG.
Wire size recommendations for the CCU:
For +28VDC (J1-A), +28 VDC RTN (J1-B), and Chassis GND (J1-C), use 20
AWG
Unless otherwise specified, for discrete signaling, use 22 AWG.
Unless otherwise specified, for twisted shielded pairs, use 22 AWG conductors.
Wire size recommendations for the IPLD:
For +28 VDC (J4-Z), +28 VDC RTN GND (J4-W), use 16 AWG
Unless otherwise specified, for signaling, use 22 AWG.
RF TX and RX Coaxial Yes 95%
Table 4-3 Cable Shielding and Termination Specifications
Cable Conductor Type
Single
Point
Multiple
Point
Minimum
Conductor
Coverage by
Shield