System Description

Table Of Contents
Page 5-6
28 Feb 2018
23-15-45
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
Aspire-200
© Honeywell International Inc. Do not copy without express permission of Honeywell.
6. Type the number next to the available NAV type.
7. To configure the NAV2 type, press the number next to the NAV2 Type
parameter, and then press ENTER.
The NAV2 Type prompt appears.
8. Type the number next to the available NAV2 type.
9. To configure the NAV3 type, press the number next to the NAV3 Type
parameter, and then press ENTER.
The NAV3 Type prompt appears.
10.Type the number next to the available NAV3 type.
11. If you have finished configuring
the HDU, restart the HDU.
To configure the NAV transmission speed:
1. In the maintenance menus, to navigate to menu 3, press CTRL + N.
2. In menu 3, to access miscellaneous EEPROM parameters, press m.
The list of miscellaneous EEPROM parameters appears.
3. To navigate the list of parameters, press CTRL + N.
4. Type the number next to Primary Nav Receive Speed, and then press ENTER.
5. To set the interface to high speed, press 1, and to set the interface to low-speed,
press 0.
6. Type the number next to Secondary Nav Receive Speed, and then press
ENTER.
7. To set the interface to high speed, press 1, and to set the interface to low-speed,
press 0.
8. Type the number next to Tertiary Nav Receive Speed, and then press ENTER.
9. To set the interface to high speed, press 1, and to set the interface to low-speed,
press 0.
10.Restart the HDU.
You can restart the HDU using menu 2, option Z.
NAV2 TYPE NOT INSTALLED 0="NOT INSTALLED" 1=INERTIAL 3=GNSS
4=HYBRID 7=AHRS 8=FMS = ?
NAV3 TYPE NOT INSTALLED 0="NOT INSTALLED" 1=INERTIAL 3=GNSS
4=HYBRID 7=AHRS 8=FMS = ?