User's Manual
Table Of Contents
- Introduction
- System Description
- System Operation
- Installation
- Test and Fault Isolation
- Maintenance and Repair
- 1. Maintenance
- 2. Repair
- 3. Instructions for Continued Airworthiness
- Appendix A: Inmarsat Satellite Beam Coverage
- Appendix B: Troubleshooting Checklist
- Appendix C: Installation Planning Checklist
- Appendix D: Installation Checklist
- Appendix E: Inmarsat Cause Codes
- Appendix F: Setting Up SBB
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal
23-15-30 1-5
8 MAY 09
Table 1-1 lists the physical characteristics and equip
ment specifications for the HSD-Xi
terminal.
Table 1-1 HSD-Xi Characteristics and Specifications
Characteristic Specification
Physical Characteristics
Size 2 MCU ARINC 600-10 Form Factor
Weight 8.8 lbs maximum
Cooling Air Unit capable of continuous duty cycle operation, with
or
without forced air-cooling provided, as per ARINC
600 specifications. Refer to 1110-E-0401.
Electrical Characteristics
Power dissipation 34 W
Input Power 115 V ac, 400Hz, 75 va
Input frequency range 1530.0 to 1559.9 MHz
Output frequency range 1626.5 to 1660.5 MHz
Receiver input impedance 50 ohms
Transceiver output
im
pedance
50 ohms
Input level operational -107 dBm to -47 dBm
Input level no damage +10 dBm
External Interfaces
Crosstalk bus ARINC 429 high-speed (100 kbps) data bus
Maintenance port RS-232
da
ta loader front and rear
connector
RS-232 serial bus supports 57.6 kbps data load
capacity
ISDN user interface 64 kbps ISDN Euro input and output
Ethernet 10BASE-T (full and half duplex)
Table 1-2 lists the environmental specifications fo
r the HSD-Xi terminal.
Table 1-2 HSD-Xi Terminal Environmental Characteristics
Characteristic Specification/Category
Temperature and Altitude A4 without cooling air, C4 with
coolin
g air
Low Operating Temperature -40 ºC (A4), -40 ºC (C4)
High Operating Temperature + 55 ºC (A4), +70 ºC (C4)
Altitude Maximum operating altitude:
15