User's Manual
Table Of Contents
- Introduction
- System Description
- 1. Purpose of Equipment
- 2. Equipment Covered
- 3. Equipment Description
- A. Applicable Documents
- B. Reference Documents
- C. Equipment Specifications
- D. Mechanical Description
- E. Electrical Description
- F. System Interface Descriptions
- G. User Interfaces
- (1) Stand-Alone Mode User Interfaces
- (2) Collins Cooperative Mode User Interfaces
- (3) Honeywell Combined Mode User Interfaces
- (4) Selective Mode User Interfaces
- (5) Multi-Channel Configurations
- (6) ISDN Circuit-Switched Data Interface
- (7) RS-232 Interface
- (8) Ethernet Data Interface
- (9) ISDN S/T Interface
- (10) Maintenance Port Interface
- H. Initiated-Self-Test
- I. Owner Requirements Table
- 4. Inmarsat System Overview
- 5. HSD Modes and Configuration Descriptions
- System Operation
- 1. Introduction
- 2. Activating HSD Transceivers
- 3. Configuring HSD Systems
- 4. Using the HSD System
- Installation
- 1. Introduction
- 2. Advisories
- 3. Pre-Installation Inspection
- 4. Unpacking and Inspecting Equipment
- 5. Cabling and Connector Requirements
- 6. ARINC 600 Trays and Connectors
- 7. Mechanical Installation
- 8. Electrical Installation
- 9. Outline/Installation and Interconnection/Contact Assignment Diagrams
- Test and Fault Isolation
- 1. Introduction
- 2. Operational and Diagnostic Testing
- 3. Troubleshooting and Fault Isolation
- 4. Adjustment/Alignment Procedures
- 5. Modification History
- Maintenance and Repair
- 1. General
- 2. Maintenance
- 3. Repair
- 4. Instructions for Continued Airworthiness, FAR 25.1529
- Appendix A: Inmarsat Satellite Beam Coverage
- Appendix B: Troubleshooting Checklist
- Appendix C: RJ-45 Cable Termination Details
- Appendix D: Installation Checklist
- Appendix E: Record of Accomplishment
- Appendix F: RF Splitter
Page 2–21
18 September 2007
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-128 High-speed Data Terminal
2. To select HCM Aero/M4 Prioritization, type 42 and then press Enter.
The system prompts you to select a service priority.
3. Set the service priority for the system as follows:
• To select M4 services as the system priority, type
1 then press Enter.
• To select Aero services as the system priority, type
0 (the number
zero) then press
Enter (as displayed in the example provided above).
A system message appears stating that the EEPROM has been updated.
This completes the configuration of service priority. You now need to
configure the LES Access Codes.
(4) Configuring System Parameters for Selective Mode
This section describes how to use the HSD Maintenance Port Utility to configure the
HSD system parameters for operation in Selective Mode.
Refer to "Test and Fault Isolation" on page 4-1 for detailed instructions on how to
connect to and use the HSD Maintenance Port Utility Program.
When all the required system parameters have been configured, “reset” or cycle the
power on the HSD to activate the new configuration.
To configure the required system parameters first establish a connection to the HSD
Maintenance Port Utility program:
• Connect a computer to the maintenance port of the HSD transceiver as described
in
"Test and Fault Isolation" on page 4-1, and then power up the system.
• Using a terminal emulation program, open the HSD maintenance utility program.
• Type the password MAINT. (The password does not appear on the screen.)
MISCELLANEOUS PARAMETERS
1 HPA-TO-ANTENNA TOTAL LOSS 11 FRONT PANEL LEDS ENABLED
2 FORWARD ID 14 MAINTENANCE PORT INVERSE VIDEO
3 GPS PROTECTION ALGORITHMS 15 MAINTENANCE PORT DEGREES SYMBOL
4 REGISTRATION REQ'D BEFORE CALLS 16 TERMINAL CATEGORY
10 NUMBER OF CHANNEL CARDS 17 VIPER ANTENNA GAIN
WHICH PARAMETER # <CTRL> N for next page ?
18 VIPER HPA/ANT LOSS 31 OBEY OXCO STATUS
24 RECEIVER CALIBRATION 42 HCM AERO/M4 PRIORITIZATION
28 RX32 ACTIVE 45 CATEGORY B LOWER FREQUENCY LIMIT
29 DEFAULT LATITUDE 46 CATEGORY B UPPER FREQUENCY LIMIT
30 DEFAULT LONGITUDE…….
WHICH PARAMETER #.? 42
HCM AERO/M4 PRIORITIZATION AERO (1=M4 0=AERO) = ? 0
EEPROM UPDATED