User's Manual

Table Of Contents
Page 2–19
18 September 2007
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-128 High-speed Data Terminal
1. Configuring the Terminal Category for Combined Mode
If the HSD transceiver does not have the recommended hardware strapping
for system configuration installed, configure the terminal category using the
HSD Maintenance Port EEPROM parameters as described in the following
procedure.
To configure the Terminal Category:
1. In Menu 3, to select misc. EEPROM parameters press M.
The Miscellaneous Parameters list appears. The available parameters
may differ depending on the version of control processor software
installed.
2. To select the Terminal Category, type 16 and then press Enter.
The Terminal Category Menu appears.
3. Type 8 for HCM Combined and then press Enter.
A system message appears stating that the EEPROM has been updated.
This completes the configuration of the terminal category.
2. Configuring Antenna Loss
To configure the Antenna Loss:
1. In Menu 3, to select misc. EEPROM parameters, press M.
The Miscellaneous Parameters list appears.
MENU 3 FIRMWARE Vx.x
L list EEPROM S list event log
M misc. EEPROM parameter F list call log
O list ORT P ocean region parameter
I set all LES id’s
<CTRL> N next menu <CTRL> O previous menu = select reports
MISCELLANEOUS PARAMETERS
1 HPA-TO-ANTENNA TOTAL LOSS 11 FRONT PANEL LEDS ENABLED
2 FORWARD ID 14 MAINTENANCE PORT INVERSE VIDEO
3 GPS PROTECTION ALGORITHMS 15 MAINTENANCE PORT DEGREES SYMBOL
4 REGISTRATION REQ'D BEFORE CALLS 16 TERMINAL CATEGORY
10 NUMBER OF CHANNEL CARDS 17 VIPER ANTENNA GAIN
WHICH PARAMETER # <CTRL> N for next page ? 16
TERMINAL CATEGORY HW STRAPPED VALUE
0=SAT906 1=STANDALONE 2=HW STRAPPING 3=MCS3000 4=MCS6000 5=MCS7000
6=MCS COMB 7=STANDALONE W/O ANTENNA 8=HCM COMBINED
9=COOPERATIVE ROCKWELL-COLLINS SAT906 10=OLD COMBINED MODE DEVELOP
11=HSD-X NETWORK 12=HSD-X NETWORK W/O ANTENNA 13=VIPER
NEW TERMINAL CATEGORY = ? 8