SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-128 High-speed Data Terminal
5 Have any changes to the system been made?
For previously installed and functional units, make note of any changes made to the
system since the last time the unit functioned without problems.
Were any new devices or systems connected to the unit?
Have any connecting devices or equipment been removed or replaced? If so, check
that all new or replaced connections are attached and configured correctly.
Have you changed service providers or re-configured the system in any way?
6 Are your Primary and Secondary LES Access Codes programmed for all Ocean
Regions?
In Control Card software versions later than 5.7, the system default for LES access codes
is set to “0” (zero), which must be configured to a valid LES access codes before operation.
Refer to
"System Operation" on page 2-1 for details.
7 Was the operational mode of the system strapped or configured correctly?
Verify that the System Mode wiring straps match the installation configuration mode, for
example Stand-Alone Mode, Honeywell Combined Mode (HCM), Cooperative Mode,
Multi-Channel or Selective Mode.