SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-128 High-speed Data Terminal
Call failure IRS information not
available
Activate
maintenance
reports 21 and 23
(See Figure 4–51)
Check that the IRS
systems are powered on
and aligned.
Check that connections to
the IRS systems are
secured.
Check the polarity of IRS
input lines.
If no IRS data is available,
use Menu 10 to manually
input navigational data to
point the antenna to a
preferred satellite location
and try the call again.
Call failure System does not log onto the
broadbeam
Activate
maintenance
reports 21 and 23
(See Figure 4–53)
Check that the IRS data is
received and valid.
Ensure that a valid FWD ID
is read
Verify correct antenna
pointing.
Ensure LES Access codes
are configured correctly.
Verify all coax
connections.
Call failure System does not log onto the
correct Ocean Region
Activate
maintenance report
21 and 23
(See Figure 4–53)
Check that the IRS data is
received and valid.
Check for antenna
line-of-sight interference.
Call failure Unit is not transmitting Activate
maintenance
reports 21 and 23
Figure 4–52 – No
Signal
Check for a defective or
loose RF cable.
Verify the Rx RF level is
acceptable.
Check RF power level
displayed in Maintenance
Port Menu Report Item 21;
signal strength should be
requested at 14.00 dBW
but in call should increase
to 22.5 dBW.
Ensure the HSD is secured
properly to the ARINC
connector in the tray.
Table 4–27. Troubleshooting and Fault Isolation
Fault Description
Maintenance
Report
Check