SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-128 High-speed Data Terminal
Table 4–27. Troubleshooting and Fault Isolation
Fault Description
Maintenance
Report
Check
RED LED
remains on
after
powering up
sequence
HPA Uncontrolled
•HPA Fault
View initial power-up
display of the HSD
Maintenance Utility
Program
In Stand-Alone
installations, verify that the
multicontrol, looped back
is wired (out to in)
In Stand-Alone
installations, check
transmit path between
RFU and HSD
HPA Error
Status
reporting invalid SSM
HPA not reporting status
word 143
HPA not reporting
maintenance word 350
HPA maintenance word
reporting ARINC error
HPA maintenance word
not reporting HGA
antenna
HPA maintenance word
reporting VSWR error
HPA maintenance word
reporting RAM error
•HPA reporting ROM
error
HPA maintenance word
reporting power supply
error
HPA maintenance word
reporting temperature
error
In menu 1, press
Y to
obtain an
explanation of the
HPA error status
Check continuity on
ARINC buses between
HSD and antenna
subsystem
Check continuity on
ARINC buses between
HSD and SDU
Verify SDI is strapped
correctly (TP5B to TP5D)
Check the external power
source is properly
connected and meets
installation requirements
Check transmit path from
HSD output (MPC1) to the
antenna subsystem (coax
cables, splitters, relays,
etc…)
Check the RFU TX output
(MPC1) connection to the
HSD input (TPC1)
Check installation location
meets the RTCA/DO-160D
environmental
specifications
Check for proper fan-tray
operation and air-cooling.
Verify the fan-tray plug
distribution is as per the
installation requirements