Page 4–75
18 September 2007
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-128 High-speed Data Terminal
10. Type the appropriate COM port (1 or 2—typically 1), and then press Enter.
11. To proceed with the load, press Enter.
Note: If you press Esc, the application aborts the software load. Only press Esc
if you want to discontinue the software load procedure.
Communication with the HSD or HSD-X transceiver is established. The following
screen appears. As shown in the example screen, a percentage (%) progress
indicator appears on the screen showing load status. Once the load is complete,
a confirmation message briefly appears on the screen indicating that the file has
been successfully loaded. The DOS window then closes and the HSD resets.
This completes the load of the Control Processor software selected in step 9.
12. When software load is finished, reset or cycle the power on the HSD of HSD-X
transceiver.
13. If no other software loads are required, proceed to Verifying the Software Load.
14. In the event that the load fails, restart the load from the beginning of the Loading
Control Processor Software Procedure. If after two attempts the load still does
not complete successfully, assume that the software disks may have been
corrupted or the software is incompatible with the hardware configuration. Contact
EMS SATCOM product support for assistance.
HSD/HST LOADER V3.0 -- Mon Mar 24 12:12:17 2003
which target ?
0 = control processor
1 = channel card #1
2 = channel card #2
3 = HPA application
4 = data i/o card
5 = HPA application with manual setup
6 = HPA application plus boot with manual setup
7 = HPA application plus boot
8 = channel card #1 boot code
9 = channel card #2 boot code
11 = channel card #1 pic code
12 = channel card #2 pic code
13 = HCM application
14 = HST ORT
15 = HSD ORT
16 = HSD-X ORT
?) 0
File name, which contains the firmware image? Adt70.bin
This download will require one of the PC's COM ports. (1, 2, etc) [1] ?
1
Connect COM1 of this PC to the maintenance port of the data terminal.
Hit <ESC> to abort, or <ENTER> to proceed
Establishing communication to the data terminal -- DO NOT CYCLE THE POWER !!
Hit ESC to abort.
DATA TERMINAL APPARENTLY READY TO ACCEPT PROGRAM
switching to 57.6 kbaud
loading adt70.bin
1% 5% 10%