SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-128 High-speed Data Terminal
When loading software to HSD units in installation environments that include an SDU,
disable the SDU (Power off or remove the sdu from the arinc tray) before beginning the
software load procedure.
Note: Refer to the applicable software release note or service bulletin for a specific list of
the software files that need to be loaded. If in doubt, verify with EMS SATCOM
product support that the software version being loaded is the latest release. The
file formats of the software presented in this manual are examples only; refer to the
applicable service bulletin for the actual files required for each specific software
load.
Note: When loading channel card software to HSD transceivers in installation
environments where the SDU has been disabled or removed, the channel card (or
cards) must be manually powered up using the HSD Maintenance Utility Program.
(1) Loading Channel Card Software
This section describes how to load channel card software on to HSD and HSD-X
transceivers.
Note: Software cannot be loaded onto an HSD-X unit using the pass-through mode
function via the HSD transceiver. Software must be loaded to an HSD-X via
the front connector or ARINC connections of the HSD-X unit.
To load channel card software
1. Connect a computer to the Maintenance Port of the HSD transceiver.
2. Turn on the computer.
3. Save the HSD Load Program file (PN 1110-SW-1021) to a folder on your PC.
(Recommended: Create a folder named HSD Load in the PC’s root directory and
save the load application file to this folder.)
4. Apply power to the HSD or HSD-X transceiver.
5. If loading software in installation environments where the SDU is disabled during
software loading, the channel cards must be manually powered up before
proceeding with the software load. Refer to "Forcing Channel Card Power Up
Procedure" on page 4-76 for detailed instructions.
6. Close all other applications running on the computer (especially programs that
use the serial COM port, e.g. HyperTerminal). The load program may not execute
successfully if other programs are running.
7. In the HSD folder, double-click on the ADT_LOAD.exe to launch the load
application.
The ADT_LOAD application opens in a DOS window and displays the “Load
Target” menu.