SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-128 High-speed Data Terminal
(3) Verifying Multi-Channel Configuration System Operation
This section provides system operational verification procedures that are specific to
Multi-Channel configuration installations.
The following system verification procedures use the HSD Maintenance Port Utility
Program to access system information.
Note: Record all test results in "Installation Checklist" on page D-1.
The following system verification procedures use the HSD Maintenance Port Utility’s
“console-mode” functionality to access system information from all of the HSD-X units
in a Multi-Channel installation.
(a) Activating “Console-Mode”
The HSD-Xs are monitored using the ”console-mode” function of the HSD
Maintenance Port Utility Program.
To remotely access an HSD-X for monitoring purposes using the “console-mode”
feature of the HSD-128 transceiver’s Maintenance Port Utility Program:
1. Connect to the HSD-128 Maintenance Port (using either the front panel or
remote access connector).
2. Open a session of the HSD Maintenance Port Utility Program using the
password MAINT.
3. In Menu 18, press X.
The application prompts you to enter the number of the HSD-X you want to
monitor.
4. Type the number of the HSD-X you want to monitor, and then press Enter.
5. Enter the password: maint
The reports screen appears for the selected HSD-X.