User's Manual
Table Of Contents
- Introduction
- System Description
- 1. Purpose of Equipment
- 2. Equipment Covered
- 3. Equipment Description
- A. Applicable Documents
- B. Reference Documents
- C. Equipment Specifications
- D. Mechanical Description
- E. Electrical Description
- F. System Interface Descriptions
- G. User Interfaces
- (1) Stand-Alone Mode User Interfaces
- (2) Collins Cooperative Mode User Interfaces
- (3) Honeywell Combined Mode User Interfaces
- (4) Selective Mode User Interfaces
- (5) Multi-Channel Configurations
- (6) ISDN Circuit-Switched Data Interface
- (7) RS-232 Interface
- (8) Ethernet Data Interface
- (9) ISDN S/T Interface
- (10) Maintenance Port Interface
- H. Initiated-Self-Test
- I. Owner Requirements Table
- 4. Inmarsat System Overview
- 5. HSD Modes and Configuration Descriptions
- System Operation
- 1. Introduction
- 2. Activating HSD Transceivers
- 3. Configuring HSD Systems
- 4. Using the HSD System
- Installation
- 1. Introduction
- 2. Advisories
- 3. Pre-Installation Inspection
- 4. Unpacking and Inspecting Equipment
- 5. Cabling and Connector Requirements
- 6. ARINC 600 Trays and Connectors
- 7. Mechanical Installation
- 8. Electrical Installation
- 9. Outline/Installation and Interconnection/Contact Assignment Diagrams
- Test and Fault Isolation
- 1. Introduction
- 2. Operational and Diagnostic Testing
- 3. Troubleshooting and Fault Isolation
- 4. Adjustment/Alignment Procedures
- 5. Modification History
- Maintenance and Repair
- 1. General
- 2. Maintenance
- 3. Repair
- 4. Instructions for Continued Airworthiness, FAR 25.1529
- Appendix A: Inmarsat Satellite Beam Coverage
- Appendix B: Troubleshooting Checklist
- Appendix C: RJ-45 Cable Termination Details
- Appendix D: Installation Checklist
- Appendix E: Record of Accomplishment
- Appendix F: RF Splitter
Page 4–62
18 September 2007
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-128 High-speed Data Terminal
F. Operational Mode and Configuration System Checks
This section describes system checks designed for specific HSD modes of operation.
(1) Verifying Cooperative Mode System Operation
This section provides system operational verification procedures that are specific to
Cooperative Mode installations.
The following system verification procedures use the HSD Maintenance Port Utility
Program to access system information.
Note: Record all test results in "Installation Checklist" on page D-1.
Note: Depending on the version of software and the system configuration installed,
the actual menus and screen displays appearing in “live” systems may differ
slightly from the illustrations provided in this document. The illustrations also
use “x.x” as a substitute for the actual firmware version.
(2) Verifying Honeywell Combined Mode System Operation
This section provides system operational verification procedures that are specific to
Honeywell Combined Mode installations.
The following system verification procedures use the HSD Maintenance Port Utility
Program to access system information.
Note: Record all test results in "Installation Checklist" on page D-1.
(a) Checking HPA Status
To check the HPA Status:
1. With the Maintenance Port Utility program activated (MAINT password
access), press the equals sign (
=) to activate the “Reports”.
2. Press Ctrl+N to scroll to report 25.
3. To toggle on the HPA ARINC I/O report, type 25.
Report 25 toggles ON.
4. Press Esc.
The “Reports” for HPA Status appears on screen. The screen refreshes every
few seconds.
5. Confirm that the report shows SSM as “normal operation” and that SDI
appears configured as HGA HPA. (See example provided above.)
6. Toggle OFF report 25. (Press = , then type 25. Report 25 appears as “OFF”).
HPA maintenance word 600002: SSM: NORMAL OPERATION SDI: HGA HPA
HPA status word 64137a: SSM: NORMAL OPERATION SDI: HGA HPA
OUTPUT POWER: 28.0 dB LESS THAN 40W
MAX. AVAILABLE RMS POWER: 2.0 dB GREATER THAN 40W
HELD POWER LINEAR CARRIER OFF BACKOFF RANGE= 31 dB