SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-128 High-speed Data Terminal
2. Once the power up messages appear:
Enter the Level 2, password: maint
3. Press the equal sign on the keyboard (=) to access the “reports” menu, then
activate report items 21 (call codes) and 23 (standard output). Remember
to save these selected items by using the “S” (save to EEPROM) command.
4. In Menu 2, press Z to reset the HSD.
The system resets and displays the power up equivalent reset messages
(as previously shown in
Figure 4–32).
5. After the reset messages appear, immediately type the password maint.
The data from the previously selected report items 21 and 23 appears.
This data refreshes on-screen every second. For easier reading of the data,
capture this information in a log file for later review.
6. Compare the output data to the sample shown in Figure 4–33.
Several parameters need to be reviewed and documented for operational
verification purposes. Refer to
"Installation Checklist" on page D-1 for a
detailed list of parameters.
7. Verify that the following system information, as shown on the “System
Initialization Display” during the test, is accurate for the HSD unit under test.
Correct forward ID displayed
Correct installation mode displayed
Correct number of channel cards listed
All channel cards trigger ocean region registration
The sample figure has been edited for clarity. A successful log on is confirmed
when the message “ACSE Successful ORR” and valid “beam” numbers are
reported, e.g. beam 4.