User's Manual
Table Of Contents
- Introduction
- System Description
- 1. Purpose of Equipment
- 2. Equipment Covered
- 3. Equipment Description
- A. Applicable Documents
- B. Reference Documents
- C. Equipment Specifications
- D. Mechanical Description
- E. Electrical Description
- F. System Interface Descriptions
- G. User Interfaces
- (1) Stand-Alone Mode User Interfaces
- (2) Collins Cooperative Mode User Interfaces
- (3) Honeywell Combined Mode User Interfaces
- (4) Selective Mode User Interfaces
- (5) Multi-Channel Configurations
- (6) ISDN Circuit-Switched Data Interface
- (7) RS-232 Interface
- (8) Ethernet Data Interface
- (9) ISDN S/T Interface
- (10) Maintenance Port Interface
- H. Initiated-Self-Test
- I. Owner Requirements Table
- 4. Inmarsat System Overview
- 5. HSD Modes and Configuration Descriptions
- System Operation
- 1. Introduction
- 2. Activating HSD Transceivers
- 3. Configuring HSD Systems
- 4. Using the HSD System
- Installation
- 1. Introduction
- 2. Advisories
- 3. Pre-Installation Inspection
- 4. Unpacking and Inspecting Equipment
- 5. Cabling and Connector Requirements
- 6. ARINC 600 Trays and Connectors
- 7. Mechanical Installation
- 8. Electrical Installation
- 9. Outline/Installation and Interconnection/Contact Assignment Diagrams
- Test and Fault Isolation
- 1. Introduction
- 2. Operational and Diagnostic Testing
- 3. Troubleshooting and Fault Isolation
- 4. Adjustment/Alignment Procedures
- 5. Modification History
- Maintenance and Repair
- 1. General
- 2. Maintenance
- 3. Repair
- 4. Instructions for Continued Airworthiness, FAR 25.1529
- Appendix A: Inmarsat Satellite Beam Coverage
- Appendix B: Troubleshooting Checklist
- Appendix C: RJ-45 Cable Termination Details
- Appendix D: Installation Checklist
- Appendix E: Record of Accomplishment
- Appendix F: RF Splitter
Page 4–46
18 September 2007
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-128 High-speed Data Terminal
B130 DEMOD channel out of range
B133 DEMOD tuning in progress
B200 Generic modem error
B201 RF error RX VHF
B202 RF error RX Lband
B204 RF error RX VHF
B208 RF error TX Lband
B210 RF error RF error
B220 RF error Ref error
B27F Mod watchdog tripped
B280 Generic voice codec errors
B281 TMS spurious interrupt
B300 Outdoor unit failure, check connections to ODU
B301 ODU error cannot set cable attenuator
B310 ODU error power response missing
B311 ODU error tune response missing
B312 ODU error HPA control response missing
B313 ODU error HPA status response missing
B314 ODU error alarm response missing
B315 ODU error burst timer response missing
B316 ODU error HPA backoff response missing
B320 ODU error alarm heat
B321 ODU error alarm burst
B322 ODU error alarm power
B323 ODU error alarm over voltage
B324 ODU error alarm reverse power
B328 ODU failed due to tx power check
B329 ODU error alarm timeout
B330 ODU error alarm timeout no trip
B400 Internal temperature of unit too high, turn off for 10 minutes
B401 Internal temperature sensor failed
B410 Mod error, handshake failure, power down/up and try again
B500 Battery charging communication failure
B501 Power supply error
B580 Battery is over temperature, charging disabled
B581 Battery temperature is now ok, charging enabled
Table 4–20. Fault Code Definitions
Inmarsat Cause
Code
Code Definition