User's Manual
Table Of Contents
- Introduction
- System Description
- 1. Purpose of Equipment
- 2. Equipment Covered
- 3. Equipment Description
- A. Applicable Documents
- B. Reference Documents
- C. Equipment Specifications
- D. Mechanical Description
- E. Electrical Description
- F. System Interface Descriptions
- G. User Interfaces
- (1) Stand-Alone Mode User Interfaces
- (2) Collins Cooperative Mode User Interfaces
- (3) Honeywell Combined Mode User Interfaces
- (4) Selective Mode User Interfaces
- (5) Multi-Channel Configurations
- (6) ISDN Circuit-Switched Data Interface
- (7) RS-232 Interface
- (8) Ethernet Data Interface
- (9) ISDN S/T Interface
- (10) Maintenance Port Interface
- H. Initiated-Self-Test
- I. Owner Requirements Table
- 4. Inmarsat System Overview
- 5. HSD Modes and Configuration Descriptions
- System Operation
- 1. Introduction
- 2. Activating HSD Transceivers
- 3. Configuring HSD Systems
- 4. Using the HSD System
- Installation
- 1. Introduction
- 2. Advisories
- 3. Pre-Installation Inspection
- 4. Unpacking and Inspecting Equipment
- 5. Cabling and Connector Requirements
- 6. ARINC 600 Trays and Connectors
- 7. Mechanical Installation
- 8. Electrical Installation
- 9. Outline/Installation and Interconnection/Contact Assignment Diagrams
- Test and Fault Isolation
- 1. Introduction
- 2. Operational and Diagnostic Testing
- 3. Troubleshooting and Fault Isolation
- 4. Adjustment/Alignment Procedures
- 5. Modification History
- Maintenance and Repair
- 1. General
- 2. Maintenance
- 3. Repair
- 4. Instructions for Continued Airworthiness, FAR 25.1529
- Appendix A: Inmarsat Satellite Beam Coverage
- Appendix B: Troubleshooting Checklist
- Appendix C: RJ-45 Cable Termination Details
- Appendix D: Installation Checklist
- Appendix E: Record of Accomplishment
- Appendix F: RF Splitter
Page 4–25
18 September 2007
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-128 High-speed Data Terminal
(d) Menu 4
In control-processor software version 7.0, the following changes were made to
Menu 4 selections (delta between version 4.5 and 7.0). No additional menu items
were added with the release of Version 7.5, Control Processor software.
• Removed Menu 4, item F, ‘force spot beam’ selection.
Figure 4–20 shows the HSD maintenance utility program Menu 4 screen display.
Table 4–12 describes the items available in Menu 4.
Figure 4–20. Menu 4 Screen Display
MENU 4 FIRMWARE V7.0
Q channel card forward ID's O set Ocean Region
S change spot beam J toggle ISDN connection
M report MUX stats
<CTRL> N next menu <CTRL> O previous menu = select reports
Table 4–12. Menu 4 Item Descriptions
Menu Item Item Description
Q: channel card
forward IDs
• Enables viewing of channel cards, # 1 and # 2 Forward IDs
O: set Ocean Region
• Allows for manual selection of satellite Ocean Regions:
AORW:
“0”
AORE:
“1”
POR:
“2”
IOR:
“3”
• To revert to programmed selection, type
–1 and press Enter
for AUTO selection
J: toggle ISDN
connection
• Used for testing and fault isolation purposes
• Connects ISDN 1 lines to Channel Card 2 (Does not work
in reverse—ISDN 2 to ISDN 1)
• Redirection only applies until the system is reset
S: change spot beam
• Enables manual selection of specific spot beams
independently assigned for each channel card
M: report MUX stats
• Not applicable
• Used for engineering debugging purposes only