User's Manual
Table Of Contents
- Introduction
- System Description
- 1. Purpose of Equipment
- 2. Equipment Covered
- 3. Equipment Description
- A. Applicable Documents
- B. Reference Documents
- C. Equipment Specifications
- D. Mechanical Description
- E. Electrical Description
- F. System Interface Descriptions
- G. User Interfaces
- (1) Stand-Alone Mode User Interfaces
- (2) Collins Cooperative Mode User Interfaces
- (3) Honeywell Combined Mode User Interfaces
- (4) Selective Mode User Interfaces
- (5) Multi-Channel Configurations
- (6) ISDN Circuit-Switched Data Interface
- (7) RS-232 Interface
- (8) Ethernet Data Interface
- (9) ISDN S/T Interface
- (10) Maintenance Port Interface
- H. Initiated-Self-Test
- I. Owner Requirements Table
- 4. Inmarsat System Overview
- 5. HSD Modes and Configuration Descriptions
- System Operation
- 1. Introduction
- 2. Activating HSD Transceivers
- 3. Configuring HSD Systems
- 4. Using the HSD System
- Installation
- 1. Introduction
- 2. Advisories
- 3. Pre-Installation Inspection
- 4. Unpacking and Inspecting Equipment
- 5. Cabling and Connector Requirements
- 6. ARINC 600 Trays and Connectors
- 7. Mechanical Installation
- 8. Electrical Installation
- 9. Outline/Installation and Interconnection/Contact Assignment Diagrams
- Test and Fault Isolation
- 1. Introduction
- 2. Operational and Diagnostic Testing
- 3. Troubleshooting and Fault Isolation
- 4. Adjustment/Alignment Procedures
- 5. Modification History
- Maintenance and Repair
- 1. General
- 2. Maintenance
- 3. Repair
- 4. Instructions for Continued Airworthiness, FAR 25.1529
- Appendix A: Inmarsat Satellite Beam Coverage
- Appendix B: Troubleshooting Checklist
- Appendix C: RJ-45 Cable Termination Details
- Appendix D: Installation Checklist
- Appendix E: Record of Accomplishment
- Appendix F: RF Splitter
Page 3–81
18 September 2007
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-128 High-speed Data Terminal
Note: MP11D: Reserved, 0 = FWD Address Comm
I
15A 10BASE-T RX+ Ethernet 10BASE-T,
RJ45-3
User Data, Ethernet
10BASE-T
I
15B 10BASE-T RX- Ethernet 10BASE-T,
RJ45-6
O
15C 10BASE-T TX+ Ethernet 10BASE-T,
RJ45-1
O
15D 10BASE-T TX- Ethernet 10BASE-T,
RJ45-2
Table 3–44. HSD-X Bottom Plug – Multi-Channel
I/O
From
Bottom
Plug
Signal Name To Description
O 1 RF, Tx Output Combiner to HSD-128 Coax Cable, RF
Transmit
I 2 115 V ac HOT Aircraft Power Source,
HOT
115 V ac 400 Hz supply
I 3 Chassis GND Aircraft Ground Aircraft Chassis Ground
I 4 115 V ac COLD Aircraft Power Source,
COLD
115 V ac 400 Hz supply
I 5 RF Rx Input Splitter from Antenna
Subsystem-DLNA
Coax Cable, RF Receive
Table 3–45. HSD-X I/O Data Strapping– Multi-Channel
MP11A MP11B MP11C I/O Config
111Invalid
110Restricted (disable Data I/O)
101MPDS (Future)
100SCPC (M4) only
011Unrestricted (recommended if there are no specific
user requirements)
010Not Assigned
001Not Assigned
000Reserved
Table 3–43. HSD-X Middle Plug Connections– Multi-Channel
I/O
From
Middle
Plug
Signal Name To Description