User's Manual
Table Of Contents
- Introduction
- System Description
- 1. Purpose of Equipment
- 2. Equipment Covered
- 3. Equipment Description
- A. Applicable Documents
- B. Reference Documents
- C. Equipment Specifications
- D. Mechanical Description
- E. Electrical Description
- F. System Interface Descriptions
- G. User Interfaces
- (1) Stand-Alone Mode User Interfaces
- (2) Collins Cooperative Mode User Interfaces
- (3) Honeywell Combined Mode User Interfaces
- (4) Selective Mode User Interfaces
- (5) Multi-Channel Configurations
- (6) ISDN Circuit-Switched Data Interface
- (7) RS-232 Interface
- (8) Ethernet Data Interface
- (9) ISDN S/T Interface
- (10) Maintenance Port Interface
- H. Initiated-Self-Test
- I. Owner Requirements Table
- 4. Inmarsat System Overview
- 5. HSD Modes and Configuration Descriptions
- System Operation
- 1. Introduction
- 2. Activating HSD Transceivers
- 3. Configuring HSD Systems
- 4. Using the HSD System
- Installation
- 1. Introduction
- 2. Advisories
- 3. Pre-Installation Inspection
- 4. Unpacking and Inspecting Equipment
- 5. Cabling and Connector Requirements
- 6. ARINC 600 Trays and Connectors
- 7. Mechanical Installation
- 8. Electrical Installation
- 9. Outline/Installation and Interconnection/Contact Assignment Diagrams
- Test and Fault Isolation
- 1. Introduction
- 2. Operational and Diagnostic Testing
- 3. Troubleshooting and Fault Isolation
- 4. Adjustment/Alignment Procedures
- 5. Modification History
- Maintenance and Repair
- 1. General
- 2. Maintenance
- 3. Repair
- 4. Instructions for Continued Airworthiness, FAR 25.1529
- Appendix A: Inmarsat Satellite Beam Coverage
- Appendix B: Troubleshooting Checklist
- Appendix C: RJ-45 Cable Termination Details
- Appendix D: Installation Checklist
- Appendix E: Record of Accomplishment
- Appendix F: RF Splitter
Page 3–74
18 September 2007
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-128 High-speed Data Terminal
O
3F OUT
Multi-Control B
IN Multi Ctrl B (TP1B), and
MA: BSU, Pin B or U, or
OA: BSU, PORT-U &
STBD-U
Multi-Control-LO to HSD
& Antenna Subsystem
I
2K Remote Reset Normally open
momentary switch—open
side. (Closed side to
MP1F)
Remote System Reset
I
3G WOW 1 TP3G Weight On Wheel, as
defined in Note 40 of
ARINC 741, Part 1.
I
3H WOW 2 TP3H
I
3J WOW Program
Select
TP3J
I
4A, 4B,
4C, 4D
System Config 1
to 4
4A, 4B, & 4C=0 (TP7K
common)
4D=1(Open)
Multi-Channel Mode
Configurations
I
4E to 4H System Config 5
to 8
Open (1) System Configuration -
not assigned
I
4J IRS-A Aircraft main IRS IRS 429 Data, Rx HI
I
4K IRS-B Aircraft main IRS IRS 429 Data, Rx LO
I
5A SDI 1 Not connected HPA Select Code for HGA
I
5B SDI 2 SDI common (TP5D) HPA Select Code for HGA
I
5D SDI Common SDI 2 (TP5B) SDI Common for HPA
select codes
I
5F FWD Address,
BIT 24 (LSB)
1=no connection,
0=Common (TP7K)
Six digit Hex ID assigned
by Inmarsat /EMS
SATCOM
I
5G FWD Address,
I
5H FWD Address,
I
5J FWD Address,
I
5K FWD Address,
BIT 20
I
6A FWD Address,
I
6B FWD Address,
I
6C FWD Address,
I
6D FWD Address,
I
6E FWD Address,
Table 3–39. HSD-128 Multi-Channel Configuration ARINC 600 Top Plug
Connections
I/O
From
Top Plug
Signal Name To Description