User's Manual
Table Of Contents
- Introduction
- System Description
- 1. Purpose of Equipment
- 2. Equipment Covered
- 3. Equipment Description
- A. Applicable Documents
- B. Reference Documents
- C. Equipment Specifications
- D. Mechanical Description
- E. Electrical Description
- F. System Interface Descriptions
- G. User Interfaces
- (1) Stand-Alone Mode User Interfaces
- (2) Collins Cooperative Mode User Interfaces
- (3) Honeywell Combined Mode User Interfaces
- (4) Selective Mode User Interfaces
- (5) Multi-Channel Configurations
- (6) ISDN Circuit-Switched Data Interface
- (7) RS-232 Interface
- (8) Ethernet Data Interface
- (9) ISDN S/T Interface
- (10) Maintenance Port Interface
- H. Initiated-Self-Test
- I. Owner Requirements Table
- 4. Inmarsat System Overview
- 5. HSD Modes and Configuration Descriptions
- System Operation
- 1. Introduction
- 2. Activating HSD Transceivers
- 3. Configuring HSD Systems
- 4. Using the HSD System
- Installation
- 1. Introduction
- 2. Advisories
- 3. Pre-Installation Inspection
- 4. Unpacking and Inspecting Equipment
- 5. Cabling and Connector Requirements
- 6. ARINC 600 Trays and Connectors
- 7. Mechanical Installation
- 8. Electrical Installation
- 9. Outline/Installation and Interconnection/Contact Assignment Diagrams
- Test and Fault Isolation
- 1. Introduction
- 2. Operational and Diagnostic Testing
- 3. Troubleshooting and Fault Isolation
- 4. Adjustment/Alignment Procedures
- 5. Modification History
- Maintenance and Repair
- 1. General
- 2. Maintenance
- 3. Repair
- 4. Instructions for Continued Airworthiness, FAR 25.1529
- Appendix A: Inmarsat Satellite Beam Coverage
- Appendix B: Troubleshooting Checklist
- Appendix C: RJ-45 Cable Termination Details
- Appendix D: Installation Checklist
- Appendix E: Record of Accomplishment
- Appendix F: RF Splitter
Page 3–40
18 September 2007
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-128 High-speed Data Terminal
I
2D BSU STBD BITE B MA: Not required
OA
: SDU, MP7K
ARINC Tx-LO BITE
From STBD BSU
I
3A to 3D HPA MUTE MA: Not required
As per avionics
manufacturer’s
documentation
HPA Mute-A & B to BSU
I
2K Remote Reset Normally Open
momentary
switch—open side
(Closed side to
MP1F)
Remote System Reset
(Optional; not
recommended for
Combined Mode)
I
3G WOW 1 TP3G Weight On Wheel, as
defined in Note 40 of
ARINC 741
I 3H WOW2 TP3H
I 3J WOW Program Select TP3J
I
4A to 4D System Config 1 to 4 System Mode
Configurations
I
4E to 4H System Config 5 to 8 Open (1) System Mode
configuration-not
assigned
I
4J IRS-A Aircraft main IRS IRS 429 Data, Rx HI
I
4K IRS-B Aircraft main IRS IRS 429 Data, Rx LO
I
5A, 5B, &
5D
SDI 1, SDI 2, & SDI
Common
As per avionics
manufacturer’s
documentation
HPA Select Code for
HGA
I
5F FWD Address, BIT 24
(LSB)
1=no connection,
0=Common (TP7K)
Six digit Hex ID assigned
by Inmarsat /EMS
SATCOM
Table 3–20. Combined/Selective Mode ARINC 600 Top Plug Connection Details
I/O
From
Top Plug
Signal Name To Description