User's Manual

Table Of Contents
Page 3–10
18 September 2007
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-128 High-speed Data Terminal
Figure 3–1. HSD-X Physical Placement Requirements
C. Environmental Requirements
The environmental requirements that must be considered during the physical placement
of the HSD and HSD-X transceivers are based on the RTCA/DO-160D Environmental
Specifications detailed in
"System Description" on page 1-1.
The standard mounting trays for the HSD and HSD-X offer a number of fan configuration
options depending on the physical placement of the LRU in the aircraft.
(1) Heating and Cooling
Refer to "System Description" on page 1-1 for a complete listing of the
RTCA/DO-160D Environmental Specifications for the HSD and HSD-X transceivers.
(a) HSD Transceivers
When selecting an installation location for the HSD transceiver, consider the
heating and cooling requirements listed below:
Power Dissipation (DC models): 275 Watts nominal, 370 Watts maximum
Power Dissipation (AC models): 275 Watts nominal, 385 Watts maximum
Cooling Air: per ARINC 600
Recommended Flow rate: 175 lbs/hr
Pressure drop: 0.05”, ± 0.025” H
2
O
(b) HSD-X Transceivers
When selecting an installation location for the HSD-X transceiver, consider the
heating and cooling requirements listed below:
Power Dissipation: 34 Watts
Cooling Air: per ARINC 600
Recommended Flow rate: 15.5 lbs/hr
Pressure drop: 0.044”, ± 0.025” H
2
O