SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-128 High-speed Data Terminal
15. Select or clear the LCP Filtering and Allow MPDS as default service check boxes
as required.
16. In the Accessible through PPPoE field, select the appropriate service option
(MPDS and ISDN, MPDS Only, None-disable, or ISDN Only).
17. Click OK.
You return to the main screen of the HSD ORT Tool.
18. Click Installation.
The Installation dialog box,
Signal Loss tab sheet appears.
19. In the HSD-X to HSD text boxes, enter the Signal Loss values for each HSD-X
unit installed in the HSD system.
Note: The installer determines this value. Refer to "Installation" on page 3-1 for
more information.
20. In the HSD-to Antenna Loss text box, enter the installation-specific HSD to
Antenna Loss value.
Note: The installer determines this value (minimum of 1 dB and maximum of
2.5 dB).
21. To exit the Installation dialog box and return to the main ORT Tool menu, click
OK. Clicking OK applies the all changed or left as default values in the Installation
dialog box, Signal Loss tab fields.
Table 2–7. DATA I/O Naming Convention for AC-Name
HSD HSD-X #1 HSD-X #2
AC-Name DataIO (default) DataIO-1 DataIO-2