SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-128 High-speed Data Terminal
Click Remove to delete selected satellite entries from the
satellite list field.
Click Update to change the data values of a satellite selected from the
existing list (the selected satellite appears highlighted).
Note: If the required data fields are not completed correctly, an error
message appears indicating incomplete or incorrect field entries.
Follow the instructions provided in the system error messages and
re-try the step.
7. Repeat steps for each satellite that requires new or revised data.
8. Click OK.
You return to the main dialog box of the HSD ORT Tool.
9. Click Data I/O.
The
Data I/O Configuration dialog box appears. The Data I/O dialog box has
two, tabbed property sheets:
IP and PPPoE.
10. If applicable, select the Get IP Address Automatically check box.
Note: If Get IP Address Automatically is selected, BASE IP Address and
Network Mask data is not required.
11. If required, in the IP property sheet text boxes, enter the IP addressing information
(
Host Name, Base IP Address, and Network Mask) that applies to your system
configuration.
12. If applicable, select the Allow Telnet check box.
Note: Telnet provides remote monitoring and maintenance of devices using a
password-protected, terminal-emulation-program session over TCP port
23 (the Telnet Port). Selecting the
Allow Telnet check box enables
remote access to the HSD using Telnet over the Ethernet port. Clearing
the
Allow Telnet check box disables this remote functionality.