eNfusion™ HSD-128 High-speed Data Terminal
secondary LES value in their systems. However, a valid Secondary LES Access
Code must be entered in the HSD system. The Secondary LES Access Code
must be the same as the Primary LES Access Code.
When operating HSD software version 5.7, DO NOT select the “Send line ends
with line feeds” option in the terminal emulation program’s ASCII Setup. (See
example dialog box presented in
Figure 2–3.) If this ASCII Sending option is
selected, the LES Access Code entered in Menu 3 using the “P” command codes
will not be updated or saved to EEPROM.
Figure 2–3. Terminal Emulation Program, ASCII Setup
HSD transceivers with earlier versions of control processor software (5.4 or
earlier) are set with a factory default LES access code of 001. When installing
and commissioning the HSD transceiver, change the factory-set default LES for
each Ocean Region to the LES access codes provided by your Inmarsat Service
Provider.
Table 2–6 provides LES access codes for the service providers providing Swift64
services at the time of publication. Contact Inmarsat directly for an up-to-date list
of LES and Swift64 service providers.
For more information visit Inmarsat’s Web site at www.inmarsat.com/swift64 or
contact their Customer Care Service at:
Telephone: +44 20 7728 1777
Fax: +44 20 7728 1142