User's Manual
Table Of Contents
- Customer Response Form
- Record of Revisions
- Service Bulletin List
- List of Effective Pages
- Introduction
- System Description
- 1. Inmarsat System Overview
- 2. Equipment Overview
- 3. Equipment Specifications
- 4. System Interfaces
- 5. User Interfaces
- 6. Software Description
- System Operation
- 1. Registering and Activating Terminals
- 2. Configuring Terminals
- A. Setting up Airborne Networks
- B. Mapping User Devices for ISDN Services
- C. IMNs
- D. MSNs
- E. Configuring User ORT Parameters with the Maintenance Port Utility (MPU)
- F. Configuring Secure ORT Parameters with the Maintenance Port Utility (MPU)
- G. Creating ORTs with the Maintenance Port Utility (MPU)
- H. Understanding CMU Messages
- I. Configuring Swift 64 LES Access Codes
- J. Removing the LED Label
- K. Activating Configurations
- L. Verifying Configurations
- 3. Using Terminals
- Installation
- 1. Advisories
- 2. Pre-Installation Inspection
- 3. Mechanical Installation
- 4. Electrical Installation
- A. Cabling and Connector Requirements
- B. Installation Wiring Notes
- (1) Source/Destination Identification
- (2) Maintenance Port Interface
- (3) Antenna Subsystem RF Interface
- (4) WOW Pins
- (5) ICAO IDs
- (6) Remote Status Panel (Optional)
- (7) System Configuration Strapping
- (8) System Mode Strap Pins Coding
- (9) Call Light Activation Strapping
- (10) Hookswitch Strapping
- (11) Priority 4 Call Strapping
- (12) Cockpit Voice Strapping
- (13) User Interfaces
- (14) System Interfaces
- C. Connection Details
- 5. Passive Intermodulation (PIM) Test
- 6. Installation and Engineering Diagrams
- 7. Connection Details
- Test and Fault Isolation
- Maintenance and Repair
- Configuring the Owners Requirements Table (ORT)
- 1. Configuring ORT Parameters Using the MPU
- A. Connecting to the MPU
- B. Configuring the ORT Part Number
- C. Configuring Cockpit Communication Parameters
- D. Configuring 4-wire Parameters
- E. Configuring POTS Parameters
- F. Configuring CEPT-E1 Parameters
- G. Configuring High Speed Data Services
- H. Configuring Ethernet Parameters
- I. Configuring Networking Parameters For Ethernet 1 and Ethernet 2
- (1) Configuring the Host Name
- (2) Configuring the Access Concentrator Name
- (3) Configuring the SNMP Server
- (4) Configuring the SNMP Community String
- (5) Configuring the TFTP Server
- (6) Configuring the DHCP Client
- (7) Configuring the DHCP Server
- (8) Configuring Telnet Access
- (9) Configuring the Managed Range
- (10) Configuring the Number of Managed Addresses
- (11) Configuring the Access Point Name
- J. Configuring Avionics Parameters
- K. Configuring Satellite Service ORT Parameters
- (1) Configuring the Forward ID
- (2) Configuring Satellite Information
- (3) Configuring GES Service Provider Information
- (4) Configuring the Frequency Table
- (5) Configuring LES Service Provider Information
- (6) Configuring the SwiftBroadband Timing Mode
- (7) Configuring the Priority Service for Channel Card One
- (8) Configuring the Service Type Priority
- L. Configuring Antenna ORT Parameters
- M. Configuring MCDU ORT Parameters
- (1) Configuring MCDU Wiring
- (2) Configuring the MCDU Input Speed
- (3) Configuring the MCDU Output Speed
- (4) Configuring the MCDU Controller Type
- (5) Configuring the MCDU Type
- (6) Configuring the MCDU Font Colour
- (7) Configuring Manual Dialing
- (8) Configuring Outgoing Call Pre-Selection
- (9) Configuring the Address Book Categories
- N. Configuring the CMU
- O. Configuring Terminal Operation
- (1) Configuring Air/Ground Status Restrictions
- (2) Configuring Transmit on Ground
- (3) Configuring Self-test in Air
- (4) Configuring Maintenance Command Execution in Air
- (5) Configuring MCDU PAST
- (6) Configuring Field Loadable Software
- (7) Configuring the Logon/Handover Policy
- (8) Configuring Logon Interrogation
- (9) Configuring High-rate R/T in Global Beam
- (10) Masking Position in Logs
- (11) Configuring HSD SAL
- P. Configuring Passive Intermodulation (PIM) Parameters
- (1) Configuring PIMBIT HGA Azimuth Offset Angle
- (2) Configuring PIMBIT IGA Azimuth Offset Angle
- (3) Configuring PIMBIT IGA Elevation Offset Angle1
- (4) Configuring PIMBIT IGA Elevation Offset Angle2
- (5) Configuring PIMBIT HGA Elevation Offset Angle1
- (6) Configuring PIMBIT HGA Elevation Offset Angle2
- (7) Configuring PIMBIT Measurement Discard Ratio
- (8) Configuring PIMBIT Failure Threshold
- (9) Configuring PIMBIT Pointing Failure Threshold
- 2. Configuring ORT Parameters Using the EMS ORT Application
- 1. Configuring ORT Parameters Using the MPU
- Appendix A: Inmarsat Satellite Beam Coverage
- Appendix B: Troubleshooting Checklist
- 1. Have you registered with a service provider to activate service?
- 2. Has your account been activated?
- 3. Is the HSD-440 Mark 2 Terminal seated properly?
- 4. Is all cabling attached correctly and securely?
- 5. Have any changes to the system been made?
- 6. Are your Primary and Secondary LES/GES Access Codes programmed for all ORs?
- 7. Was the operational mode of the system strapped or configured correctly?
- 8. Are the SIM cards activated?
- 9. Is the APN set?
- 10. Are GES preferences correctly set?
- Appendix C: RJ45 Cable Termination Details
- Appendix D: Installation Planning Checklist
- Appendix E: Installation Checklist
- Appendix F: CMU Messages
- Appendix G: International Access and Country Codes
- Appendix H: Inmarsat Cause Codes
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion® HSD-440 Mark 2 Terminal
23-15-30 3-14
3 JUN 10
• IRS#1 A TP4J
• IRS#1 B TP4K
• IRS#2 A TP5C*
• IRS#2 B TP5E*
You can configure IRS#2 as a secondary IRS bus, or an input bus for the
AES ID.
(b) Antenna Interface
The ARINC 741 antenna subsystem BSU is connected to the HSD-440 Mark 2
Terminal as
specified in Table 3-11.
Table 3-11 HSD-440 Mark 2 Terminal to BSU Interconnects
Signal Name
Signal Source
Signal
Destination
HSD-440 Mark
2 Terminal
Mechanical
HG
A
Phased-Array or
Conformal HGA
HPA MUTE A
Top/Port BSU-G TP3A
STBD BSU-G TP3C
HPA MUTE B
Top/Port BSU-H TP3B
STBD BSU-H TP3D
BSU BITE A
BSU-W(G)* Port BSU-W TP2A
STBD BSU-W TP2C
BSU BITE B
BSU-X(H) Port BSU-X TP2B
STBD BSU-X TP2D
Multi-Control A TP3E BSU-T(A)
Multi-Control B TP3F BSU-U(B)
*L
etters in (brackets) represent EMS Aviation AMT-50 BSU pin designations
Top/Port (T/P):
Refers to Mechanical (fin-mount) HGA Subsystem
Port:
Refers to Phased Array (Fuselage-mount) or Port side of Dual (side)
Conformal-mount, HGA subsystem
Starboard (STBD):
Refers to starboard side of Dual (side) Conformal-mount HGA subsystem
NOTE:
If a third MCDU is installed, the HSD-440 cannot use the side mount
antennas because the input is allocated to either the third MCDU or the
starboard BSU Bite.