User's Manual

Table Of Contents
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion® HSD-440 Mark 2 Terminal
23-15-30 1-18
3 JUN 10
"Test and Fault Isolation" on page 4-35 provides a detailed description of the two
levels of user access and the menus, re
port selections, functions, and system
diagnostic procedures of the HSD-440 Mark 2 Terminal MPU.
I. Fault Indicator LED
Table 1-7 provides a description of the fault indicator LED functions.
Table 1-7 HSD-440 Mark 2 Terminal LED Output Designations
LED
Signa
l
Label Color Indication Description
LED1 Power On Green Normal operation: on.
HPA output is greater than 30
dBm: flashes at 1 Hz.
Power on: HSD-440 Mark 2 Terminal supply voltage is
active.
Self-test: flashes at 1 Hz alternately with the Fault
LED.
LED2 Fault Red Fault: Fault condition as described in "Fault Indicator LED"
on page 1-18.
Self-test: flashes once per second alternately with the Power
On
LED.
A failure in the HSD-440 Mark 2 Terminal may be due to a number of fault conditions.
Whe
n fault condition is detected, the HSD-440 Mark 2 Terminal activates a red, Fault
LED. Some of the potential fault conditions are:
•CP RAM
CP Application code CRC
CC power up
•CP D-UART
CP ARINC Chipset
PSU Power rail
Previous Power Up CP RAM
PSU Over temperature
OCXO Warmup
PA Over Current
PA Voltage Driver
PA Over temperature shutdown
PA 12VDC STATUS DISCRETE
SDU Configuration Module
CP Boot Code CRC
DIO Boot