User's Manual

Table Of Contents
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion® HSD-440 Mark 2 Terminal
23-15-30 1-9
3 JUN 10
16.5.1.6 Normal Frequency Variation, 360 Hz to
800 Hz
A(WF)
16.5.1.7 DC Content A(WF)
16.5.1.8 Voltage Distortion A(WF)
16.5.2.1 Abnormal Operating Condition A(WF)
16.5.2.2 Abnormal Frequency and Voltage
Condition
A(WF)
16.5.2.3 Transient/Voltage Surge—Abnormal A(WF)
16 Power Input (dc) Z
16.6 Normal Operating Conditions A
16.6.1.1 Emergency Operation A
16.6.1.1 Ripple Voltage A
16.6.1.3 Momentary Power Interruptions A
16.6.1.4 Normal Surge Voltage A
16.6.2.1 Abnormal Operating Conditions A
16.6.2.3 Momentary Undervoltage Operation A (No damage)
16.6.2.4 Abnormal Surge Voltage Z
16.7.1 Current Harmonic Emissions from
Loads
(ac)
A(WF)H
17 Voltage Spike A—600 V, and repeated at 1000 V
18 Audio Frequency Conducted
Susceptibility
Power Input (115 V ac) K(NF)
Power Input (28 V dc) Z
19 Induced Signal Susceptibility (ac) ZW
Induced Signal Susceptibility (dc) ZC
20 Radio Frequency Susceptibility RR
21 Emission of RF Energy M
22 Lightning Induced Transient
Susceptibility
A3J33
23 Lightning Direct Effects X
24 Icing X
25 Electrostatic Discharge (ESD) A —Modified to apply 4kV to all connector
pins connecting to other equipment
26 Fire Flammability C—Modified to include compliance with 14
CFR (FAR) 25.853a and 25.869(a) including
amendment 25-72
Table 1-2 HSD-440 Mark 2 Terminal RTCA/DO-160E Environmental Characteristics
Section Environmental Condition Category/Comment