To load an ORT file into the HSD-440 Mark 2 Terminal:
1. Connect a computer to an Ethernet port and the Maintenance Port on the
HSD-440 Mark 2 Terminal.
2. Copy the ORT file to the computer.
3. Start a HyperTerminal session to the Maintenance port of the HSD-440 Mark 2
Terminal.
Section c: "Interface Requirements" on page 4-38 provides the settings for this
connection.
4. To access the Maintenance Port Utility, type the password maint.
The password does not appear on the screen.
5. To navigate to Menu 2, press CTRL + N.
6. To allow tftp access to the terminal, in Menu 2, press l.
7. At the prompt, type the new password allowtftp.
A message confirms that tftp is allowed for ten minutes.
8. On your computer, click Start, and then click Run.
The Run dialog box appears.
9. In the Open field, type cmd.
The Command window appears.
10.Navigate to the directory that includes the new ORT file.
11. To load the ORT file, type tftp -i xxx.xxx.xxx.xxx put filename.
xxx.xxx.xxx.xxx represents the IP address of the Ethernet 1 port.
filename represents the name of the new ORT file.
When the tftp application loaded the file to the HSD-440 Mark 2 Terminal, a short
message confirms the number of bytes transferred.
12.To transfer the ORT parameters to the SCM, in Menu 3, press r.
13.At the prompt to transfer the ORT parameters to the SCM, type yesido.
The number of transferred bytes indicates the transfer progress.
The ORT file load is complete.