User's Manual

Table Of Contents
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion® HSD-440 Mark 2 Terminal
23-15-30 6-26
3 JUN 10
To configure the CMU wiring:
1. In the list of ORT parameters, type the number next to the CMU #x WIRED
parameter, and then press ENTER.
The prompt: CMU #x WIRED? where x equals 1 or 2 appears.
2. To indicate that the CMU #1 or CMU #2 can be wired, type 1, or to indicate that
the CMU #1 or CMU #2 cannot be wired, type 0, and then press ENTER.
The default for the CMU #1 WIRED parameter is YES (wired) and for the CMU
#2 WIRED parameter is NO (not wired).
(2) Configuring the CMU Input Speed
You can configure the input bus speed to high rate or low rate. The input speed
parameter is in the secure partition of the ORT.
To configure CMU input speed:
1. In the list of ORT parameters, type the number next to the CMU INPUT SPEED
SELECT parameter, and then press ENTER.
2. To set the CMU input bus speed to a high rate, type 1, or to set the CMU input
bus speed to a low rate, type 0, and then press ENTER.
The default is low rate.
(3) Configuring the CMU Output Speed
You can configure the output bus speed to high rate or low rate. The output speed
parameter is in the secure partition of the ORT.
To configure CMU output speed:
1. In the list of ORT parameters, type the number next to the CMU OUTPUT SPEED
SELECT parameter, and then press ENTER.
2. To set the CMU output bus speed to a high rate, type 1, or to set the CMU output
bus speed to a low rate, type 0, and then press ENTER.
The default is low rate.
(4) Configuring the CMU-SDU Join/Leave Word
The HSD-440 Mark 2 Terminal can send join/leave words periodically or only on
logon and logoff events. The CMU-SDU join/leave word parameter is in the secure
partition of the ORT.
NOTE: This parameter supports Universal brand CMU that reports a SAL that is
different than the one it accepts when using a Williamsburg protocol.
To configure the CMU-SDU join/leave word:
1. In the list of ORT parameters, type the number next to the CMU-SDU
JOIN/LEAVE WORD TRANSMISSION parameter, and then press ENTER.
2. To transmit join/leave words periodically, type 1, or to transmit join/leave words
on events, type 0, and then press ENTER.
The default is PERIODIC.