SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion® HSD-440 Mark 2 Terminal
23-15-30 6-8
3 JUN 10
(1) Configuring CEPT-E1 Interface
The CEPT-E1 wiring parameter indicates whether the CEPT-E1 interface is wired.
The CEPT-E1 wiring parameter is in the secure ORT.
To configure CEPT-E1 wiring:
1. In the list of ORT interface parameters, type the number next to the CEPT E1
WIRED parameter, and then press ENTER.
2. To indicate the CEPT-E1 interface is wired, type 1, or to indicate the CEPT-E1
interface is not wired, type 0, and then press ENTER.
The default is YES.
(2) Configuring the CEPT-E1 Interface Type
The CEPT-E1 interface can connect to a variety of equipment. The available options
are:
Not installed
•ARINC 746
•ITU
The CEPT-E1 interface type parameter is in the secure ORT.
To configure the CEPT-E1 interface type:
1. In the list of ORT parameters, type the number next to the CEPT E1 INTERFACE
TYPE parameter, and then press ENTER.
2. To indicate that the CEPT-E1 interface type is not installed, type 0, or to indicate
the CEPT-E1 interface type is ARINC 746, type 1, or to indicate the CEPT-E1
interface type is ITU, type 2, and then press ENTER.
The default is ARINC 746.
G. Configuring High Speed Data Services
(1) Configuring the Default PPPoE Service
The HSD-440 Mark 2 Terminal can use a default PPPoE service name if the client
does not provide the service name. The default PPPoE service parameter is in the
secure ORT.
To configure the default PPPoE service:
1. In the list of ORT parameters, type the number next to the DEFAULT PPPOE
SERVICE parameter, and then press ENTER.
2. Type a default service name, up to 60-characters in length, and then press
ENTER.
The default PPPoE service name is PacketData.
(2) Configuring SCPC High Speed Service
The HSD-440 Mark 2 Terminal can provide access to Swift 64 SCPC service through
Ethernet. The parameter to allow SCPC sessions is in the secure ORT.