User's Manual

Table Of Contents
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion® HSD-440 Mark 2 Terminal
23-15-30 6-7
3 JUN 10
To configure the 4-wire noise level:
1. In the list of ORT parameters, type the number next to the 4-WIRE #1 NOISE
LEVEL parameter, and then press ENTER.
2. At the prompt, define the default setting for the 4-wire #1 comfort noise insertion
level by typing one of the following values: 0, -40, -50, or -60, and then press
ENTER.
The default level is -50.
To configure the 4-wire speaker level:
1. In the list of ORT parameters, type the number next to the 4-WIRE #1 SPEAKER
LEVEL parameter, and then press ENTER.
2. At the prompt, define the 4-wire #1 speaker volume, by typing a value between
0 and 100, and then press ENTER.
The default level is 50, which equals a 2.5 mW output.
To configure the 4-wire microphone level:
1. In the list of ORT parameters, type the number next to the 4-WIRE #1 MIC LEVEL
parameter, and then press ENTER.
2. At the prompt, type in a value between 1 and 100, and then press ENTER.
The default level is 70.
To configure the 4-wire sidetone level:
1. In the list of ORT parameters, type the number next to the 4-WIRE #1 SIDETONE
LEVEL parameter, and then press ENTER.
2. At the prompt, define the default setting for the 4-wire #1 sidetone level by typing
a value between 1 and 100, and then press ENTER.
The default level is 50.
E. Configuring POTS Parameters
(1) Configuring POTS
You can enable and disable POTS with the POTS service parameter. The POTS
service parameter is in the secure ORT.
To configure POTS:
1. In the list of ORT parameters, type the number next to the POTS SERVICE
parameter, and then press ENTER.
2. To enable POTS, type 1, or to disable POTS, type 0, and then press ENTER.
The default is ENABLED.
F. Configuring CEPT-E1 Parameters
You can enable the CEPT-E1 interface with the MPU.