SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion® HSD-440 Mark 2 Terminal
23-15-30 6-4
3 JUN 10
A. Connecting to the MPU
You can configure ORT parameters manually or
using the EMS ORT Application through
the HSD-440 terminal MPU.
To connect to the MPU:
1. Connect your computer to the maintenance port of the HSD-440 Mark 2 Terminal
with a ma
intenance cable.
2. Start a terminal emulator session with the following parameters:
Baud rate—19200
No. of bits—8
Parity—None
Stop bits—1
Flow control—None
3. When the HSD-440 Mark 2 Terminal boots, type the password maint.
NOTE: The password does not appear on the screen.
NOTE: You can configure secure and user ORT parameters using
maintenance-level access. The user-level access password, user, allows
you to see all the ORT parameters but you can only configure the user-level
parameters.
Menu 1 of the MPU appears. You can navigate the menus to configure ORT
p
arameters.
4. To navigate to M
enu 3, press CTRL + N.
5. In Menu 3, type the number next to se
t CP ORT parameter, and then press ENTER.
A list of ORT parameters appears.
B. Configuring the ORT Part Number
You can configure a part number for the secure and user ORT. The HSD-440 Mark 2
Te
rminal displays the part number when it boots up.