SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion® HSD-440 Mark 2 Terminal
23-15-30 4-85
3 JUN 10
HSD-440 Mark
2 Terminal is
operating
outside the
normal
environmental
specifications
Channel card temperature fault Activate report
21 or 23
Check channel card temperature;
temperatures over 50° C may
cause the HSD-440 Mark 2
Terminal to shut down.
Check that the fan tray is
operational.
Verify that the tray plug
distribution is the same as
presented in the installation
requirements.
Calls do not
complete and
connection is
not established
Channel Congestion (fault code
2024) Note: applies to Swift 64
only.
Activate reports
21 and 23
Wait five minutes and try the call
again.
Contact the LES/GES to verify
congestion. To contact the
LES/GES operator, dial 33,
POUND KEY.
No call request sent Activate report
52
Verify that the call dial string is
correct; pressing POUND KEY at
the end of the dialing string signals
the system to send the call.
Check that the HSD-440 Mark 2
Terminal is transmitting by
ensuring the LED power indicator
flashes on and off (1
Hz) during a
call request.
Check that the ISDN, Ethernet, or
POTS cable is connected
correctly and securely.
No dial tone
heard in
handset
Activate report
21
Confirm that ISDN lines are wired
correctly.
Verify that handset connection is
secure.
Wait a few minutes for the system
to warm up, then log on and try
your call again.
Check that IRS data is available.
Verify that the terminal has
completed beam registration.
Table 4-24 Troubleshooting and Fault Isolation (Continued)
Fault Description
Maintenance
Report
Check