User's Manual

Table Of Contents
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion® HSD-440 Mark 2 Terminal
23-15-30 4-81
3 JUN 10
Call failure IRS information not available Activate
maintenance
reports 21 and
23
Check that the IRS systems are
powered on and aligned.
Check that connections to the IRS
systems are secured.
Check the polarity of IRS input
lines.
If no IRS data is available, use
Menu 10 to manually input
navigational data to point the
antenna to a preferred satellite
location and try the call again.
System does not log on to the
global beam
Activate
maintenance
reports 21 and
23
Check that the IRS data is
received and valid.
Make sure that a valid FWD ID is
read.
Verify that the antenna is pointing
in the correct direction.
Make sure that LES/GES access
codes are configured correctly.
Verify all coaxial connections.
System does not log on to the
correct OR
Activate
maintenance
reports 21 and
23
Check that the IRS data is
received and valid.
Check for antenna line-of-sight
interference.
Terminal is not transmitting Activate
maintenance
reports 21 and
23
Check for a defective or loose RF
cable.
Verify that the Rx RF level is
acceptable.
Check RF power level displayed
in maintenance port menu report
21; the EIRP should be requested
at 14.00
dBW, but when in call,
power level should increase to
22.5
dBW and then level off to
approximately 16
dBW.
Make sure that the HSD-440
Mark 2 Terminal is secured
properly to the ARINC connector
in the tray.
Table 4-24 Troubleshooting and Fault Isolation (Continued)
Fault Description
Maintenance
Report
Check