User's Manual

Table Of Contents
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion® HSD-440 Mark 2 Terminal
23-15-30 4-71
3 JUN 10
3. To access the reports menu, press EQUAL SIGN, and then activate reports
21 (call codes) and 23 (standard output).
Remember to save these selected items by pressing S (save to EEPROM).
4. To reset the HSD-440 Mark 2 Terminal, in Menu 2, press Z, and then
immediately type the password maint when the reset messages appear.
The data from the previously selected reports 21 and 23 appears. This data
refreshes on-screen every second. You can capture this information in a log
file for later review or pause the display by pressing SCROLL LOCK or
highlighting part of the viewed data.
5. Compare the output data to the sample shown in Figure 4-21.
You can review and document several parameters for operational verification
purposes. Refer to
"Installation Checklist" on page E-1 for a detailed list of
parameters.
6. Verify that the following system information, as shown on the System
Initialization Display during the test, is accurate for the HSD-440 Mark 2
Terminal under test.
FWD ID
Installation mode
Number of channel cards
All channel cards trigger OR registration
(c) On-Air Voice/Data Call Verification
Once the system has logged on, place a test voice and/or data call. Refer to
"System Operation" on page 2-1 for detailed call procedures. Verification of all
aircraft communication functions is recommended. Record the test call result on
"Installation Checklist" on page E-1.
NOTE: For the purposes of providing a sample display, an ISDN voice call is
documented.
(d) On-Air Voice/Data Call Verification Procedure
To place an on-air voice or data call:
1. Make sure that the maintenance port reports 21 and 23 are activated.
2. Place a test call.
3. Observe the maintenance port messages, and verify that they are similar to
the sample provided in
Figure 4-21.