User's Manual

Table Of Contents
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion® HSD-440 Mark 2 Terminal
23-15-30 4-63
3 JUN 10
(4) Configuration Parameters Verification
You can verify the system configuration parameters. For additional connection and
access information, see
"Connection Requirements" on page 4-37. Verify and
document the parameters using the lists in "Installation Checklist" on page E-1.
2.0 Voltage levels CAUTION: WHEN POWER IS APPLIED TO THE RACK, THE
FAN ENERGIZES.
Check voltage levels:
28 V dc: between BP2 (positive) and BP3 (return)
or
115 V ac: between BPI (115-H) and BP7 (115-C)
3.0 IRS Input IRS wiring:
Inertial system wired to TP4J (A) and TP4K (B)
IRS format:
ARINC 429 Interface
4.0 Configuration
Strap Pins
SDI:
Strapped for HGA, Pin TP5B to TP5D
System configuration:
Figure 3-9 and Figure 3-10
ICAO ID:
User specific address obtained from the aircraft registration
WOW: optional
5.0 Ethernet 1 and 2 Wired or strapped to RJ45 distribution points
Optional—other service may be preferred
6.0 ISDN 1 Wired or strapped to RJ45 distribution points
Optional—other service may be preferred
7.0 CEPT-E1 Wired to CTU - optional
8.0 Remotes
(optional but
recommended)
Remote reset switch
Maintenance port, remote access
Power and fault indicators
9.0 RF coaxial Rx input cable loss from DLNA J2 to HSD-440 Mark 2 Terminal at
BP12
Tx output cable loss from HSD-440 Mark 2 Terminal at MPC1 to
DLNA J3
10.0 Multi-control and
BITE from antenna
subsystem
Antenna manufacturer and model
Multi-Control loopbacks installed at TP3E and TP3F
Table 4-23 HSD-440 Mark 2 Terminal Electrical Verification Checklist (Continued)
STEP Item Checked Verification Description