User's Manual

Table Of Contents
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion® HSD-440 Mark 2 Terminal
23-15-30 3-20
3 JUN 10
Table 3-14 HSD-440 Stand-Alone Terminal Top Plug Connection Details
I/O
From
Top
Plug
Signal Name To Description
I 1A CMU 1 Input A CMU 1 TP1A CMU 1 RX A
I 1B CMU 1 Input B CMU 1 TP1B CMU 1 RX B
O 1C CMU 1/2 Output A CMU 1/2 MP2C CMU 1/2 TX A
O 1D CMU 1/2 Output B CMU 1/2 MP2D CMU 1/2 TX B
I 1E ARINC 615 Input A
ARINC 615 Data Loader
I 1F ARINC 615 Input B
O 1G ARINC 615 Output A
O 1H ARINC 615 Output B
I 1J ARINC 615 Link A
O 1K
ARINC 615 Link B
(GND)
I 2A BSU Top/Port BITE A
Mech. Steered Antenna
(MA): BSU, Pin G or W or
Other Antenna (OA): BSU,
PORT-W and starboard-P
ARINC Tx-HI BITE from
BSU
I 2B BSU Top/Port BITE B
MA: BSU, Pin H or X, or OA:
BSU, PORT-X and STBD-R
ARINC Tx-LO BITE
from BSU
I 2C
BSU Starboard (STBD)
BITE A or MCDU 3 Input
A
MA: Not required
OA: BSU, PORT-P and
STBD-W
ARINC Tx-HI BITE from
BSU
I 2D
BSU STBD BITE B
or MCDU 3 Input B
MA: Not required
OA: BSU, PORT-R and
STBD-X
ARINC Tx-LO BITE
from BSU
O 2E
Spare 1 ARINC 429
Output A
O 2F
Spare 1 ARINC 429
Output B
2G Hookswitch method
I 2H
Spare 2 ARINC 429
Input A
I 2J
Spare 2 ARINC 429
Input B
I 2K Remote Reset
Normally open momentary
switch-open side.
(Closed side to MP1F)
Remote System Reset