User's Manual

Table Of Contents
23-15-30 4-50
24 JUN 09
EMS SATCOM
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-440 High-speed Data Terminal
Table 4-22 Troubleshooting and Fault Isolation
Fault Description
Maintenance
Report
Check
Red LED
remains on
after powering
up sequence
HPA fault View initial
power-up
display of the
HSD-440
terminal MPU
Verify that:
the terminal is well seated in the
ARINC tray
the LES ID Code is programmed
(Menu 3, option I).
HPA error
status
reporting invalid SSM
HPA not reporting
status word 143
HPA not reporting
maintenance word
350
HPA maintenance
word reporting
ARINC error
HPA maintenance
word not reporting
HGA antenna
HPA maintenance
word reporting
Voltage Standing
Wave Ratio (VSWR)
error
HPA maintenance
word reporting
Random Access
Memory (RAM) error
HPA reporting
Read-only Memory
(ROM) error
HPA maintenance
word reporting power
supply error
HPA maintenance
word reporting
temperature error
To obtain an
explanation of
the HPA error
status, in Menu
1, press Y
Check that the external power source
is properly connected and meets
installation requirements.
Check that the transmit path from
HSD-440 terminal output (MPC1) to
the antenna subsystem (e.g., coaxial
cables, splitters, and relays).
Check that the installation location
meets the RTCA/DO-160E
environmental specifications.
Check for proper fan-tray operation
and air-cooling.
Verify the fan-tray plug distribution is
as per the installation requirements.