eNfusion™ HSD-440 High-speed Data Terminal System Description, Installation, and Maintenance Manual MN-1252-33077, Revision C00 This document provides configuration and operational procedures for the equipment listed below.
PROPRIETARY STATEMENT This document contains information which is proprietary and confidential to EMS SATCOM (EMS Technologies Canada, Ltd.). Neither this document nor the information contained within may be used for any purpose other than the purpose for which it was prepared. Neither this document nor the information contained within may be disclosed or copied without the prior written permission of EMS SATCOM. © 2007, 2009 EMS Technologies Canada, Ltd. All Rights Reserved.
CUSTOMER RESPONSE FORM To help us improve the quality of our product documentation, EMS SATCOM would appreciate your comments and suggestions on this publication. Please complete the following customer survey and send to EMS SATCOM at: EMS SATCOM 400 Maple Grove Road Ottawa, ON K2V 1B8 E-mail: techdocs@emssatcom.
Blank Page 23-15-30 CR-2 24 JUN 09
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal RECORD OF REVISIONS When revisions are received, insert revised pages, record the date, and initial.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Blank Page 23-15-30 RR-2 24 JUN 09
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal SERVICE BULLETIN LIST Service Bulletin Number Subject Manual Rev. Manual Rev.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Blank Page 23-15-30 SBL-2 24 JUN 09
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal LIST OF EFFECTIVE PAGES * An asterisk indicates pages changed, added, or deleted by the current revision. F indicates a right foldout page with a blank back.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Blank Page 23-15-30 LEP-2 24 JUN 09
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal TABLE OF CONTENTS INTRODUCTION 1. Illustration of Equipment............................................................................... INTRO-2 2. Product Terms and Conditions .................................................................... INTRO-2 3. Reference Documents ................................................................................... INTRO-2 4.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal L. Remote Reset ................................................................................................................ 1-14 8. User Interfaces...................................................................................................... 1-14 A. ISDN Circuit-Switched Data Interface ............................................................................ 1-14 B.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal K. Activating Configurations ............................................................................................... 2-11 L. Verifying Configurations ................................................................................................. 2-11 3. Using Terminals .................................................................................................... 2-12 A.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal (1) Heating and Cooling.................................................................................................... 3-4 (2) Fan Tray Requirements .............................................................................................. 3-4 D. Chassis Grounding .......................................................................................................... 3-5 5.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal (1) General ..................................................................................................................... 4-23 (2) Test Setup Procedure................................................................................................ 4-24 (3) Post Test ...................................................................................................................
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal D. Repair Facility Approvals ................................................................................................. 5-1 E. Return for Repair Information .......................................................................................... 5-1 (1) Warranty Returns ........................................................................................................
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal LIST OF FIGURES Figure INTRO-1 HSD-440 Terminal................................................................................... INTRO-2 Figure 1-1 Simplified Aeronautical Satellite Communications System ....................................... 1-2 Figure 1-2 HSD-440 Terminal Interfaces ..................................................................................
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Figure 3-11 (Sheet 1). HSD-440 Terminal Interconnection and Contact Assignment Drawing (1252-B-3110, Rev D)............................................................................................................... 3-33 Figure 3-12 (Sheet 2). HSD-440 Terminal Interconnection and Contact Assignment Drawing (1252-B-3110, Rev D).....................................................................
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Figure 4-33 Top/Port Antenna Status (reports 18, 19, and 20 activated) ................................. 4-49 Figure A-1 Satellite ORs ............................................................................................................. A-1 Figure A-2 Inmarsat I3 Satellite Beam Coverage—Composite Map...........................................
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Blank Page 23-15-30 TC-10 24 JUN 09
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal LIST OF TABLES Table INTRO-1 EMS SATCOM Reference Documents.................................................... INTRO-2 Table 1-1 HSD-440 TE Characteristics and Specifications ....................................................... 1-4 Table 1-2 HSD-440 Terminal RTCA/DO-160E Environmental Characteristics ......................... 1-6 Table 1-3 HSD-440 Terminal Operational Software ................
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table 3-14 Chime and Light Strapping for Cockpit Voice ........................................................ 3-17 Table 3-15 ARINC 600 Top Plug Connection Details .............................................................. 3-18 Table 3-16 ARINC 600 Middle Plug Connection Details .........................................................
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table F-10 Join/Leave Word Bits .............................................................................................. F-8 Table F-11 Fault Summary Word 1 Bits .................................................................................... F-9 Table F-12 Fault Summary Word 2 Bits ..................................................................................
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Blank Page 23-15-30 TC-14 24 JUN 09
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal INTRODUCTION This manual provides the specifications, principles of operation, and information necessary to install an eNfusion™ HSD-440 High-speed Data Terminal in Stand-Alone Mode.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal 1. Illustration of Equipment Figure INTRO-1 HSD-440 Terminal 2.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal 4. Acronyms and Abbreviations The following acronyms and abbreviations are used in this document.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal FMS Flight Management System FRLP Forward Link Pairs FWD ID Forward ID GES Ground Earth Station GND Ground HGA High-gain Antenna HPA High Power Amplifier HTML Hyper Text Markup Language Hz Hertz I/O Input/Output ICAO International Civil Aviation Organization ICD Interconnection Drawing IMN Inmarsat Mobile Number INS Inertial Navigational System IOR Indian Ocean Region
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal MSB Most Significant Bit MSN Mobile Serial Number MSN Multiple Subscriber Number NAT Network Address Translation NO normally open NT Network Terminator O&I Outline and Installation Diagram OA Other Antenna OCXO Oven Controlled Crystal Oscillator OEM Original Equipment Manufacturer ORR Ocean Region Registration ORT Owner Requirements Table PAST Person Activated Self Test P
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal 5.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal WARNING: ASSOCIATED SATELLITE COMMUNICATIONS EQUIPMENT RADIATES HIGH FREQUENCY RADIATION AND POSES A RADIATION HAZARD OF 1.6 GHZ. SERVICE PERSONNEL MUST EXERCISE CARE TO KEEP CLEAR OF THE ANTENNA'S BEAM WHILE PERFORMING OPERATIONAL TESTS OR INSTALLATION VERIFICATION PROCEDURES. DO NOT APPROACH WITHIN 8 FEET (2.5 METRES) OF THE ANTENNA DURING ANTENNA OPERATION (TRANSMISSION).
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Blank Page 23-15-30 INTRO-8 24 JUN 09
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal SYSTEM DESCRIPTION This section includes basic information about the HSD-440 terminal, including the following sections: 1.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Figure 1-1 Simplified Aeronautical Satellite Communications System Satellite communication systems provide users with long-range voice and data communication by accessing global satellite and ground communications networks. Inmarsat is an international organization that operates and maintains multiple geostationary satellites and satellite networks.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal 2. Equipment Overview The HSD-440 terminal is a scalable, high-speed data, satellite communications terminal that provides world-wide voice and data services to aircraft through a high-speed communication link with the Inmarsat Satellite Network.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal The HSD-440 terminal has three ports that support the following interfaces: EURO ISDN S/T, Ethernet (10BASE-T), and POTS.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table 1-1 HSD-440 TE Characteristics and Specifications (Continued) Characteristic Specification Power consumption Maximum: 460 W NOTE: Of this power consumption, 400 W is dissipated internally and 60 W of RF power is dissipated externally. Frequency Frequency band Minimum: 300 Hz Typical: 400 Hz Maximum: 800 Hz Tx: 1626.5 to 1660.5 MHz Rx: 1525.0 to 1559.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table 1-1 HSD-440 TE Characteristics and Specifications (Continued) Characteristic Specification Antenna to DLNA loss Maximum: 0.3 dB DLNA gain Minimum: 53 dB Maximum: 60 dB Maximum: 1.8 dB DLNA noise DLNA to HSD-440 terminal Minimum: total Rx total loss Maximum: 6 dB HSD-440 terminal to Minimum: antenna total Tx cable loss Maximum: including DLNA insertion loss 1 dB 2.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table 1-2 HSD-440 Terminal RTCA/DO-160E Environmental Characteristics (Continued) Section Environmental Condition Category 4.6.2 Decompression Test A2 4.6.3 Over Pressure Test A2 (modified) 5.3.1 Temperature Variation B 6.3.2 Humidity B (modified) 7.0 Operational Shock and Crash Safety B 7.2.1 Operational Shock B 7.3 Crash Safety Impulse B 7.3.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table 1-2 HSD-440 Terminal RTCA/DO-160E Environmental Characteristics (Continued) Section Environmental Condition Category 16.5.2.1 Abnormal Operating Conditions A(WF)H 16.5.2.2 Momentary Under Voltage Operation A(WF)H 16.5.2.3 Abnormal Surge Voltage A(WF)H 17.4 Voltage Spike A 18.0 Audio Frequency Conducted Susceptibility [K(WF)Z] 19.3 Induced Signal Susceptibility ZW 20.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table 1-3 HSD-440 Terminal Operational Software EMS SATCOM Part Number* Description LI-1252-33222 HSD-440 (1252-A-3420-02) Software Control Document L1-1252-33374 HSD-440 (1252-A-3420-03) Software Control Document 1252-SW-3305 HSD-440 Terminal data I/O software 1252-SW-3315 Control processor software 1210-A-0039 CC 1 Aero SBB channel card software 1210-A-0038-03 CC 1 1210-A-0039 CC 2 1
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal The HSD-440 terminal contains a communications switch that supports Inmarsat Swift64 Mobile ISDN and MPDS service within an 8-MCU assembly built in accordance to ARINC 600 specifications. The HSD-440 terminal uses the ARINC 429 multi-control bus to interface with the ACU/BSU to control the RF antenna and obtain antenna-subsystem status information over the Built-in Test Equipment (BITE) lines.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Figure 1-2 HSD-440 Terminal Interfaces A. Source Destination Identification (SDI) The SDI is provided to the HPA as per ARINC 741 specifications. B. ICAO IDs and Forward IDs The ICAO ID is a 24Bit address that identifies the AES on the network much like a FWD ID. Each aircraft has a single unique ICAO ID.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal C. Weight-On-Wheel (WOW) Pin Wiring WOW discretes indicate when an aircraft is on the ground and are used for flight data-logging purposes. These discretes are not required on the typical installation, as equivalent data indicating the aircraft is airborne is available (for example, true track and groundspeed IRS information) and supplied to the HSD-440 terminal.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal G. CMU Each HSD-440 terminal can be connected to up to two CMUs. The CMUs operate in two modes: it can select from a number of Satellite Service Providers rather than Inmarsat only, or it can operate with no preferred Satellite Service Provider. The HSD-440 terminal exchanges information with the CMU over ARINC 429 interfaces.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal K. Fault Conditions A failure in the HSD-440 terminal may be due to a number of fault conditions. Upon detection of a fault condition, the HSD-440 terminal activates its red, Fault LED. The potential fault conditions are as follows: • Channel card fault • HPA fault • Internal ROM fault • Internal RAM fault • Over temperature fault L.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal The Swift64 channel card supports communications with two, 64 kbps, ISDN B channels on the ISDN interface. If the channels are busy or in-call, the request for service is denied. Several ISDN interface options are shown in Figure 1-3. In the illustrated example, the ISDN port is used for circuit-switched services (Swift64 Mobile ISDN) or SBB voice.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal C. ISDN S/T Interface HSD-440 terminals provide one ISDN S/T physical interface that supports up to seven external connections to TA or TE devices. NOTE: An HSD-440 terminal data I/O card type 4 uses one S/T bus device connection for system use. You can install RJ45 interface connectors in the cabin area to facilitate connection to the ISDN interface.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal 10. Modes of Operation The HSD-440 terminal currently operates in Stand-Alone Mode only. In Stand-Alone Mode, the HSD-440 terminal controls both the internal HPA and antenna. The system supports up to two channels in multiple combinations of Swift64 ISDN and Swift64 MPDS service or one channel SBB. The maximum number of simultaneous Swift64 ISDN service channels is two.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Blank Page 23-15-30 1-18 24 JUN 09
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal SYSTEM OPERATION This section provides basic information on registering and operating the HSD-440 terminal, including the following sections: 1.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal (2) Identifying the Service Category and Terminal Type Register HSD-440 terminals as Category A systems. Table 2-1and Table 2-2 list the terminal type, frequency category, and currently supported service types for the HSD-440 terminal stand-alone mode installations.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal D. Registering Terminals Contact your Inmarsat service provider and ask for a Registration for service activation of Aircraft Earth Station form. With this form, you can register for both Swift64 services and Aero H+ services. Both of these activations are required for the terminal to operate. The services available depend on your service provider.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal HSD-440 terminals support connection to a multitude of user devices, allowing the user to customize their system. Because each equipment setup is different, the HSD-440 terminal uses routing codes to make sure that incoming calls (whether data or voice) reach the appropriate device.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal The numbering of IMNs varies from one type of Inmarsat service to another. For troubleshooting purposes, understanding the IMN format can assist in verifying that the correct service type is assigned to connecting devices.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table 2-5 System Assignments for Incoming Calls Entry C. Periph MSN TID Call Type Redir 2 ISDN NO_ID\ 91 800124 Mobile aero 64k speech 3 ISDN 10\ 51 800622 Mobile aero 64k UDI 4 ISDN 11\ 52 800622 Mobile aero 64k UDI 5 ISDN 12\ 53 800622 Mobile aero 64k UDI 6 ISDN NO_ID\ 51 800622 Mobile aero 64k UDI 7 Bonded NO_ID\ 51 800622 Mobile aero 64k UDI 8 ISDN
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal 4. To select Stand-Alone, press 1, and then press ENTER. A system message appears stating that the EEPROM has been updated. This completes the configuration of the terminal category for Stand-Alone Mode. 5. To activate the new configuration, reset the HSD-440 terminal. E. Configuring the APN (Access Point Name) The APN is the gateway between the SBB core network and the internet.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table 2-6 Inmarsat Swift64 LES Operator and Access Codes OR Land Earth Station Operator Country AOR-E AOR-W IOR POR Vizada USA 001 001 001 001 Stratos UK/Canada 002 002 002 002 Stratos (Auckland LES) New Zealand Xantic (Burum LES) Netherlands 012 012 012 012 Xantic (Perth LES) Australia (1) Changing LES Access Codes using the Control Processor Software To change all of
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal 6. Type the Forward ID, and then press ENTER. NOTE: The HSD-440 terminal must be reset for the Forward ID to take effect. H. Configuring ORs Each OR provides access to specific services. ORs must be configured to support SBB where SBB services are available. Table 2-7 lists the regions where SBB services are available at the time of publishing.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal To select one OR: 1. Connect to the MPU of the HSD-440 terminal—see "Terminal MPU" on page 4-2 for more information about connecting to the MPU. 2. To navigate to Menu 4, press CTRL + N. 3. To set ORs, press O. 4. To select an OR, type the number of that OR. I.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal 8. To assign a priority to Swift64 and SBB services, press the key corresponding to a priority setting shown below. The prompt for channel card two configuration appears. 9. To save changes, reset the HSD-440 terminal. J. Removing the LED Label A label covers the LES Access Codes LEDs. You can remove this label once you have configured the LES Access Codes. K.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal 3. Using Terminals This section describes how to: • Place Swift64 voice and fax calls using the ISDN interface of the HSD-440 terminal • Use the MPDS and Mobile ISDN data connections • Operate the MCDU • Operate Cockpit Communications A.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal • Area Code (and City Code, if applicable): Use the PSTN routing number assigned to the area (and if applicable, city) of your call destination. • POUND SIGN (#): To signal the system to send the call, at the end of the telephone dial string, press or enter POUND SIGN.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table 2-9 Dial Code Prefixes for System Overrides Dial Code Prefix Reason for Override Use this Dial Code Prefix to override the default LES configured in the system.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal C. Operating the MCDU The MCDU interface includes output and input ports, the screen, and the keyboard. NOTE: The following descriptions apply to a Universal MCDU. Other MCDU types may differ slightly. (1) Output Ports The MCDU transfers its identification and commands to the HSD-440 terminal using 32 bit words and a 12-14.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal • The CLR key: this key clears any text you type into the scratchpad. • The NEXT PAGE key: this key brings up the next page of a menu if one is available. You can program the other keys in the keyboard according to your requirements.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal (7) Modifying Logon Settings You can control how the HSD-440 terminal logs onto the network with the MCDU. (a) Viewing the Logon Status The logon status defines whether the HSD-440 terminal is currently logged on or logged off. To view the logon status: 1. On the second page of the MCDU’s main menu, press the key next to AERO LOGON. The SATCOM AERO LOGON menu appears, as shown in Figure 2-4.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal To change the logon mode: 1. On the second page of the MCDU’s main menu, press the key next to AERO LOGON. The SATCOM AERO LOGON menu appears. 2. Press the key next to LOGON MODE until the MCDU displays the desired logon mode. 3. Press the key next to SAVE. (d) Changing Logon Satellite ID You can change the satellite ID to which the HSD-440 terminal will log on.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal To view the status menu for a channel: 1. On the second page of the MCDU’s main menu, as shown in Figure 2-5, press the key next to AERO STAT to view the SATCOM AERO STAT menu or press the key next to HSD STAT to view the SATCOM HSD STAT menu. The SATCOM AERO STAT menu is shown in Figure 2-6. The SATCOM HSD STAT menu is shown in Figure 2-7.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Figure 2-7 SATCOM HSD STATUS Menu 2. On the SATCOM AERO STAT menu or the SATCOM HSD STAT menu, press the key next to the channel for which you wish to view the status. The menu for Aero Card 2, Channel 1 is shown in Figure 2-8. The menu for HSD Card 1, Channel 1 is shown in Figure 2-9. Similar menus are available for the remaining channel cards.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Figure 2-9 SATCOM HSD CARD1 CH1 STAT Menu On the channel status menu (Figure 2-8 and Figure 2-9), you can view the following detailed information about the operation of a channel: • Logon status • Call termination code • Transmitter Effect Isotropic Radiated Power (EIRP) • Receiver carrier-to-noise ratio • Service type • Number of bits transmitted per second (kbps) • Number of bits re
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal (b) Viewing the Call Termination Code The call termination code is a two-digit number that corresponds to a call termination reason, such as a line failure. NOTE: Call Termination Code is not available for Aero channels. To view the call termination code for HSD channels: • On the SATCOM HSD STAT menu, press the key next to channel for which you wish to view the call termination code.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal To view the number of bits being received per second: • On the SATCOM AERO STAT menu or SATCOM HSD STAT menu, press the key next to channel for which you wish to view the number of bits being received per second. The number of bits being received per second are displayed on the line below RX KBPS. When a circuit switched service has been selected or configured, the MCDU screen displays no data.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Figure 2-10 SATCOM HEADSET CONFIG Menu NOTE: The numbers move up and down by increments and decrements of 5. 2. To increase or decrease the speaker, microphone, sidetone, and noise insertion levels, press the keys next to DWN and UP. 3. Press the key next to SAVE. (b) Initiating a Person Activated Self Test (PAST) CAUTION: INITIATING A PAST DROPS ANY VOICE OR DATA CALLS THAT ARE IN PROGRESS.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Figure 2-11 SATCOM DIAG Menu 2. To initiate the PAST, press the key next to PAST. D. Cockpit Communications This section provides instructions for making calls with the MCDU and 4-wire voice services available in the aircraft’s cockpit. The cockpit communications system operates with a headset in the aircraft’s cockpit.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal 1. Accepting Calls in PTT Mode You can use the MCDU and ACP to accept incoming calls, including when another call is in progress. The combination of lights and chimes that alert you to an incoming call depends on the way in which the HSD-440 terminal was strapped during its installation. To accept a call in PTT mode: 1.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal 2. To end the call: • On the MCDU, press the key next to END. or • On the ACP, assert the PLACE/END CALL 1 switch or open the PTT 1 switch. 2. Making New Calls in PTT Mode Making calls using the HSD-440 terminal is similar to placing an international telephone call. Air-to-ground telephone numbers include an international access code, country code, and area code.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal 3. To dial the call: • On the MCDU, press the key next to DIAL NOW. or • On the ACP, assert the PLACE/END CALL 1 switch or close the PTT 1 switch. 4. To end the call: • On the MCDU, press the key next to END. or • On the ACP, assert the PLACE/END CALL 1 switch or open the PTT 1 switch. 3.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Figure 2-14 SATCOM TEL CAT 1 (Page 1 of 20) 3. Press the key next to the entry you want to dial. The SATCOM ENTRY menu appears, as shown in Figure 2-15. Figure 2-15 SATCOM ENTRY Menu (Page 1 of 100) 4. To load the telephone number, press the key next to LOAD TO DIAL. The MCDU’s main menu appears, as shown in Figure 2-16.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Figure 2-16 SATCOM MAIN MENU (Page 1 of 2) 5. To dial the call: • On the MCDU, press the key next to DIAL NOW. or • On the ACP, assert the PLACE/END CALL 1 switch or close the PTT 1 switch. 6. To end the call: • On the MCDU, press the key next to END. or • On the ACP, assert PLACE/END CALL 1 switch or open the PTT 1 switch.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal • On the MCDU, press the key next to END. To accept a call in Latched mode when another call is in progress: 1. To accept the call, on the first page of the MCDU’s main menu, press the key next to ACCEPT. The original call ends. 2. To end the call: • On the ACP, open the PTT 1 switch or assert the PLACE/END CALL 1 switch. or • On the MCDU’s main menu, press the key next to END. 2.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal 3. Making Calls from the Telephone Directory in Latched Mode You can make voice calls from the numbers you have saved in the MCDU’s telephone directory. To make a call from the telephone directory in Latched mode: 1. On the first page of the MCDU’s main menu, press the key next to TEL DIR. The SATCOM TEL DIR menu appears. 2. Press the key next to CATEGORY to select a phone book.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal 8. Press the key next to PRIORITY repeatedly until the priority you want to associate with this telephone number appears. NOTE: When you designate a telephone number as the ATC telephone number, any other telephone number that was designated as ATC loses that designation. Only one telephone number can be designated as the ATC telephone number. 9.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Blank Page 23-15-30 2-34 24 JUN 09
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal INSTALLATION This section describes the procedures required to install HSD-440 terminals on an aircraft, including the following sections: 1.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table 3-1 lists the recommended installation kits for typical installations.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal This section contains the information required to plan the physical placement of the HSD-440 terminals. The Outline and Installation diagrams, shown in Figure 3-7 and Figure 3-8, illustrate the physical and mechanical specifications of the HSD-440 terminal. In typical aircraft installations, the HSD-440 terminal assembly fits into standard ARINC, 8-MCU mounting trays.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal C. Environmental Requirements The environmental requirements that must be considered during the physical placement of the HSD-440 terminals are based on the RTCA/DO-160E Environmental Specifications detailed in "System Description" on page 1-1.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Figure 3-2 Fan Tray Plug Configuration (black = installed, white = removed) D. Chassis Grounding The HSD-440 terminal tray-mounted assemblies must be electrically bonded to the airframe. Make sure that the mating surfaces are free from contaminants such as paints or other non-conductive elements.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal (a) Power Requirements The HSD-440 terminal can operate from the aircraft’s +28 V dc or 115 V ac, 400 Hz (nominal) power supply. If both power sources are connected, the terminal will use the 115 V ac supply. (b) Ground Requirements Improper grounding can lead to ground loops and induced Electromagnetic Interference (EMI) or Radio Frequency Interference (RFI).
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table 3-2 Cable Shielding and Termination Specifications (Continued) Cable Function Conductor Type (Typical) Single Point Multiple Point Minimum Conductor Coverage By Shield Serial data Twisted pair, stranded Yes 85% Ethernet data Twisted pair, stranded Yes 85% ISDN data Twisted pair, stranded Yes 85% Discrete Lines Single conductor, stranded N/A N/A RF TX and RX Coaxial Yes
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Refer to "Test and Fault Isolation" on page 4-1 for information on how to connect and use the maintenance port, including equipment requirements, connection and cabling requirements, software loading instructions, and configuration details.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table 3-4 WOW Pin Wiring Table (Continued) Pin Name and Location Aircraft Status CLOSED OPEN CLOSED Not valid—Default in-air OPEN OPEN CLOSED On-ground CLOSED CLOSED OPEN On-ground OPEN CLOSED OPEN Not valid—Default in-air CLOSED OPEN OPEN Not valid—Default in-air OPEN OPEN OPEN In-air Use of the WOW discretes enable the HSD-440 terminal to determine whether the aircraft
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Figure 3-3 ICAO ID, Hex to Binary Conversion A pin strapped to the same potential as TP7K (ICAO address common) is considered as a logical 0, whereas an open circuit pin is considered as a logical 1.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal (f) Remote Status Panel (Optional) An optional remote status panel may be installed when HSD-440 terminals are located in inaccessible or remote locations. The installation of a remote status panel is recommended as it provides visual indications of the power and faults for each terminal. A remote reset switch for HSD-440 terminals can also be installed and located with the remote status panel.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Figure 3-5 Remote LED Panel Circuit (g) User Interfaces To facilitate user access to the HSD-440 terminal interfaces, install the following connectors in the appropriate cabin area. 1. ISDN Interface Install an RJ45 connector in the cabin area for user connections to the ISDN interface. 2.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table 3-5 RJ45 Wiring Details Service SIGNAL EURO ISDN PIN ETHERNET 10BASE-T CABLE ECS PIN OTHER CABLE ECS OTHER RX+ 3 White White/green 3 White White/orange stripe RX- 6 Blue Green 6 Green Orange/white stripe or solid orange TX+ 4 White Blue 1 White White/green stripe TX- 5 Orange White/blue 2 Brown Green/white stripe or solid Green Figure 3-6 RJ45 Connector Te
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table 3-6 Configuration Pin Summary Pin Number TP4A to D Name Function System Config 1 to 4 System mode NOTE: The logic for the System Configuration pins is reverse to the logic explained in ARINC 741 Characteristic Attachment 1-4, Note 19. • Pins marked 0 are signaled by strapping to Address Common (TP7K). • Pins marked 1 are signaled by an open circuit-no connection.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table 3-8 HSD-440 Terminal to BSU Interconnects Signal Name Signal Source Signal Destination HSD-440 Mechanical Phased-Array or Terminal HGA Conformal HGA HPA MUTE A HPA MUTE B BSU BITE A BSU-W(G)* BSU BITE B BSU-X(H) Port BSU-G TP3A STBD BSU-G TP3C Port BSU-H TP3B STBD BSU-H TP3D Port BSU-W TP2A STBD BSU-W TP2C Port BSU-X TP2B STBD BSU-X TP2D Multi-Control A TP3E BSU-T(A)
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal the ORT (instead of setting a program pin on the HSD-440 A600 connector as there are none available). If no information is available from the ORT, then the bus speed shall default to low. (k) MCDU Interface Table 3-10 shows the strapping for the MCDU.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table 3-13 Priority 4 Call Configuration Strapping Pin Number TP4F Name Function Inhibit Priority 4 Calls Determines whether priority 4 calls are inhibited. When these calls are inhibited, incoming calls at priority 4 are not allowed, and outgoing priority 4 calls are elevated to the next priority and then placed.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal 7. Connection Details This section includes connection details for the HSD-440 terminal operating in Stand-Alone Mode. A. Stand-Alone Mode Connection Details Table 3-15, Table 3-16, and Table 3-17 show the top, middle, and bottom plug connection details for HSD-440 terminals operating in Stand-Alone Mode.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table 3-15 ARINC 600 Top Plug Connection Details (Continued) I/O From Top Plug Signal Name To Description I 3A Top/Port HPA MUTE A MA: Not required OA: BSU, PORT-G HPA Mute-A, Port BSU I 2K Remote Reset I 3A Top/Port HPA MUTE A MA: Not required OA: BSU, PORT-H HPA Mute-A, Port BSU I 3B Top/Port HPA MUTE B MA: Not required OA: BSU, PORT-H HPA Mute-B, Port BSU I 3C STBD HPA MUTE
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table 3-15 ARINC 600 Top Plug Connection Details (Continued) I/O From Top Plug Signal Name To I 5E Spare 1 Input B I 5F I 5G ICAO Address, BIT 24 1 = no connection ICAO Address, BIT 23 0 = common (TP7K) I 5H ICAO Address, BIT 22 I 5J ICAO Address, BIT 21 I 5K ICAO Address, BIT 20 I 6A ICAO Address, BIT 19 I 6B ICAO Address, BIT 18 I 6C ICAO Address, BIT 17 I 6D ICAO
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table 3-16 ARINC 600 Middle Plug Connection Details I/O From Middle Plug Signal Name To Description O 1A Power LED Output 1 Remote status panel HSD-440 terminal-Power On (Optional) O 1B Fault LED Output 2 Remote status panel HSD-440 terminal-Fault (Optional) Discrete Common 1C Channel Available 1D Switch HI current from chime 1E Switch LO current to chime O 1F Discrete Common
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table 3-16 ARINC 600 Middle Plug Connection Details (Continued) I/O I From Middle Plug 3F Signal Name To Description MCDU 2 input MCDU 2 J4-28 B MCDU 2 RX B O 3G Call light 2 Future I 3H Mic on 2 Future I 3J Go-ahead / Chime reset I 3K Place/End 2 I/O 4A POTS 1 TIP I/O 4B POTS 1 RING 2-wire Analog Phone RING (RJ-11, Pin 3) I/O 4C POTS 2 TIP I/O 4D POTS 2 RING 2-wire Ana
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table 3-16 ARINC 600 Middle Plug Connection Details (Continued) I/O From Middle Plug Signal Name To O 6G 10BASE-T Tx+ Ethernet 10BASE-T RJ45, Pin 1 O 6H 10BASE-T Tx- Ethernet 10BASE-T RJ45, Pin 2 I 6J 10BASE-T Rx+ Ethernet 10BASE-T RJ45, Pin 3 I 6K 10BASE-T Rx- Ethernet 10BASE-T RJ45, Pin 6 O 7A 10BASE-T Tx+ Ethernet 10BASE-T, RJ45-1 O 7B 10BASE-T Tx- Ethernet 10BASE-T, RJ45-2 I
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Blank Page 23-15-30 3-24 24 JUN 09
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Figure 3-7 (Sheet 1).
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Blank Page 23-15-30 3-26 16 JUN 09
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Figure 3-8 (Sheet 2).
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Blank Page 23-15-30 3-28 16 JUN 09
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Figure 3-9 (Sheet 1).
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Blank Page 23-15-30 3-30 16 JUN 09
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Figure 3-10 (Sheet 2).
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Blank Page 23-15-30 3-32 16 JUN 09
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Figure 3-11 (Sheet 1).
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Blank Page 23-15-30 3-34 16 JUN 09
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Figure 3-12. (Sheet 2).
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Blank Page 23-15-30 3-36 16 JUN 09
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal TEST AND FAULT ISOLATION This section provides the information required to determine the operational readiness of the HSD-440 terminals and aid service personnel in diagnosing system faults, including the following sections: • Operational and Diagnostic Testing • Troubleshooting and Fault Isolation • Adjustment/Alignment Procedures • Modification History The operational and diagnostic test
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table 4-1 List of Required Test Equipment Item Equipment Specification Quantity Computer Standard VT-100 386 CPU, 20 MHz or higher VT-100 terminal emulation program HyperTerminal©, Serial communication program ProComm Plus©, or using an RS-232 port equivalent Cable, maintenance port Special interface cable See "Connection Requirements" on page 4-3 1 1 Remote access maximum cable 1 lengt
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal (2) Connection Requirements This section describes specific cabling requirements needed to connect to and use the HSD-440 terminal MPU. (a) Cabling Notes The HSD-440 terminals provide two options for physical connection to the HSD-440 terminal maintenance port and MPU: direct connection and remote connection.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Figure 4-1 Remote Connection, Maintenance Cable Figure 4-2 Direct Connection, Maintenance Cable (c) Interface Requirements A standard VT100 compatible terminal running an emulator program (such as HyperTerminal, ProComm Plus, or similar) provides the user interface to the HSD-440 terminal MPU. The RS-232 terminal connection settings for HSD-440 terminal maintenance ports are listed in Table 4-5.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table 4-5 Terminal Connection Settings (Continued) Parameter Setting No. of bits 8 Parity None Stop bits 1 Flow Control None (3) Accessing the MPU Access to the MPU menus is password protected. Each password permits access to a different level of the program.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal (d) Selecting Reports The reports available through the MPU enable users to view information about the configuration and status of the HSD-440 terminal. This information is used to troubleshoot the communication system on the aircraft. 1. To open the list of possible system reports, press EQUAL SIGN. A list of reports appears. Active reports show as toggled on.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table 4-6 Menu 1 Item Descriptions Menu Item X: override forward id/ICAO address Description Used in testing and fault isolation. Enter a test or alternate FWD ID or ICAO ID to use during fault isolation procedures. Resetting the HSD-440 terminal or cycling the power cancels this function. Y: explain error status Reports error status when failure LED is illuminated.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table 4-7 Menu 2 Item Descriptions (Continued) Menu Item K: desired az veh-rel velocity Description Activates continuous antenna azimuth sweep at a set elevation, as entered with menu item E. Azimuth sweep velocity entered as deg/sec value. NOTE: When combined with a signal-monitoring reports selection, sweep the antenna for maximum signal strength to determine optimum location coordinates.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table 4-8 Menu 3 Item Descriptions Menu Item L: list EEPROM Description Displays a list of all system EEPROM parameters and their corresponding values (this function is READ only). Certain parameters are set using Menu 3, item M selection. C: clear event log Clears all events and system fault codes stored in non-volatile RAM. F: list call log Displays call log files for HSD-440 terminal.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal MISCELLANEOUS PARAMETERS 1 HPA-TO-ANTENNA TOTAL LOSS 2 FORWARD ID 3 GPS PROTECTION ALGORITHMS 10 NUMBER OF CHANNEL CARDS 11 FRONT PANEL LEDS ENABLED 14 MAINTENANCE PORT INVERSE VIDEO 15 MAINTENANCE PORT DEGREES SYMBOL 16 TERMINAL CATEGORY WHICH PARAMETER # 46 51 52 53 54 55 56 57 20 21 22 29 30 31 42 45 N for next page CATEGORY B UPPER FREQUENCY LIMIT SDU INPUT POWER OFFSET OUTPUT POWER
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table 4-9 Menu 3, Item M EEPROM Parameter Descriptions (Continued) Parameter Number 15 16 Parameter Name Maintenance port degrees symbol Terminal category Description Offers a choice of displaying the letter D or the degree symbol ° when viewing the lat/long information displayed in the Reports output: • Select 0 to use the letter D; e.g., 180.0 D. • Select 1 to use a degree symbol °; e.g.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table 4-9 Menu 3, Item M EEPROM Parameter Descriptions (Continued) Parameter Number Parameter Name Description 57 PSU current intercept Not modifiable by the end-user in any mode of operation. 58 Qual PA backoff Not modifiable by the end-user in any mode of operation. 59 Classic AERO manual boot Not modifiable by the end-user in any mode of operation.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table 4-10 Menu 4 Item Descriptions Menu Item Item Description Q: channel card forward IDs Enables viewing of channel cards 1 and 2 FWD IDs and ICAO address. S: change spot beam Enables manual selection of specific spot beams independently assigned for each channel card. M: report MUX stats Not applicable: Used for engineering debugging purposes only.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table 4-11 Menu 10 Item Descriptions Menu Item L: simul INS lat Description Simulates a latitude by overriding the data received from the aircraft INS. H: simul INS heading Simulates aircraft heading by overriding the data received from the aircraft INS. P: simul INS pitch Simulates aircraft pitch by overriding the data received from the aircraft INS.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal MENU 13 FIRMWARE Vx.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal MENU 15 FIRMWARE Vx.x V request channel card versions D channel card serial number B channel card RSSI mode G A_TI query W request burst counter N next menu O previous menu = select reports Figure 4-11 Menu 15 Screen Display Table 4-13 Menu 15 Item Descriptions Menu Item V: request channel card versions Item Description Displays software versions for a selected channel card.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table 4-14 Menu 21 Item Descriptions Menu Item Item Description P: get channel card ethernet parms Displays the Ethernet parameters of the channel card, including the MAC address, the IP address, the gateway IP address, the host name, the DHCP status, and the DHCP server IP address. B: request SBB configuration Displays the SwiftBroadband configuration.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal 1 2 3 4 5 6 7 8 9 10 11 12 OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF messages to card #1 OFF hex output to card #1 OFF responses from card #1 OFF hex input from card #1 OFF card #1 misc info sb antenna arinc input sb antenna maintenance word sb antenna status word channel card call status channel card THA codes channel card errors INS input 13 14 15 16 17 18 19 20 21 22 23 24 OFF OFF
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal 95 OFF vt100 debugging 96 OFF INS data rate 107 OFF unusual channel card msgs 108 OFF channel card rf pwr detect 109 OFF channel card power SU's 110 OFF underdraft debugging 111 OFF miscellaneous digital outputs 112 OFF arinc labels 113 OFF channel card sw loads 114 OFF all channel card THA codes 115 OFF OCXO state toggles 116 OFF DATA I/O passthrough mode 117 118 119 120 121 122 123 124 125 126
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal (7) Activating Maintenance Reports In Level 1 menu access, report 23 (standard output) is automatically generated when the EQUAL SIGN is pressed. Once activated, the report data output is repeated on the computer display at one-second intervals. Level 2 maintenance access provides more flexibility in the use of the reports function.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table 4-15 Report 23 Item Descriptions Report 23 Item Number Description 1 IRS lat/long as interpreted by the HSD-440 terminal 2 Aircraft pitch angle, where UP is positive 3 Aircraft roll angle, where clockwise is positive 4 Aircraft true heading; where the nose of the aircraft is pointing, based on yaw offset 5 Aircraft true track; direction the aircraft is flying—not necessarily the d
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Select channel 1, channel 2, Both channels, or X to deselect all channels. For channel card 2, you will select channel 3, channel 4, Both channels, or X to deselect all channels NOTE: Depending on the version of software installed and the user's selection of reports, the MPU reports displayed may differ from those shown in Figure 4-16. CHAN #3: C/No=52.2 dB Hz sig=-16.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal 4. Report 21 Report 21 displays the call code information for the HSD-440 terminal. Figure 4-18 shows an example of report 21. Table 4-17 describes the items in report 21. 15:56:23 #2 456DEF E4 start 400110 14.00 dBW CT SP ocean region registration 2.0 C 52 dB Hz 15:56:24 #1 123ABC E5 start 400110 14.00 dBW CT SP ocean region registration 2.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal The procedures assume that the technical personnel are familiar with the test equipment used and can operate the equipment to produce the required inputs and obtain the required results (indications). Refer to the detailed operating procedures and descriptions of the HSD-440 terminal MPU included in this section.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table 4-19 Post Test Procedure Step Action 1.0 Save the log file of the test results (or data) for future reference. 2.0 Remove power from the HSD-440 terminal that was tested and from all other test equipment. 3.0 Disconnect test equipment from the HSD-440 terminal. 4.0 Replace the maintenance-port connector cover (if it was removed during the test setup).
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table 4-21 HSD-440 Terminal Electrical Verification Checklist STEP 1.0 Item Checked Verification Description Power connections 28 V dc polarity or 115 V ac polarity Chassis ground @ BP8—resistance measurement 2.0 Voltage levels CAUTION: WHEN POWER IS APPLIED TO THE RACK, THE FAN ENERGIZES.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal (5) Configuration Parameters Verification You can now verify the system configuration parameters. For additional connection and access information, see "Connection Requirements" on page 4-3. Verify and document using "Installation Checklist" on page E-1. (a) Parameter Verification Procedure • From Menu 3, press H (list SCM/CP ORT), and then press 1 (CP EEPROM ORT).
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal MENU 3 HSD-440 L list EEPROM E reset EEPROM M misc. EEPROM parameter N EMS serial number G clear call log P ocean region parameter Q search call log K set CP ORT parameter N next menu O FIRMWARE V11.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal SATELLITE TABLE: LES ACCESS AORW: AORE: POR: IOR: SAT 4: SAT 5: SAT 6: SAT 7: CODE TABLE: LES 1 NETWORK LES 1 NETWORK LES 1 NETWORK LES 1 NETWORK LES 1 NETWORK LES 1 NETWORK LES 1 NETWORK LES 1 NETWORK ID ID ID ID ID ID ID ID 0 0 0 0 0 0 0 0 NO NO NO NO NO NO NO NO NAME NAME NAME NAME NAME NAME NAME NAME HIT 'H' for MORE GES PRIORITY TABLE: ENTRY #1 AORE Eik ENTRY #2 AORE Aussaguel ENTRY #3
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal (c) Initial Computer Power up Display With the computer connected and configured to accept maintenance port data, power-up the HSD-440 terminal, and verify the initial power-up screen displays, as shown in Figure 4-20.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal KERNEL V1.4 -- Wed Feb 21 08:58:08 2007 TESTING RAM ......RAM OK. CONFIDENTIAL PROPERTY OF EMS TECHNOLOGIES CANADA, LTD. USE AND DISTRIBUTION LIMITED SOLELY TO AUTHORIZED PERSONNEL. The use, disclosure, reproduction, modification, transfer or transmittal of this work for any purpose, in any form, or by any means without the written permission of EMS Technologies Canada, Ltd.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal (7) System On-Air Checks Conduct system on-air checks to confirm voice and data call capabilities through the satellite and ground station network. Additional testing confirms that proper signal level parameters are obtained through the antenna subsystem. (a) Preparation Before attempting on-air testing procedures: 1. Complete and confirm all service provider registration and activation. 2.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal 6. Verify that the following system information, as shown on the System Initialization Display during the test, is accurate for the HSD-440 terminal under test. • FWD ID/ICAO ID • Installation mode • Number of channel cards • All channel cards trigger OR registration The example figure has been edited for clarity.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal CARD #2 LOGGING TEXT [02] 0922 ALO: Received user-initiated log on request (auto-select) CARD #2 LOGGING TEXT [00] 0923 ALO: User-initiated log on request ACCEPTED CARD #2 LOGGING TEXT [02] 0924 ALO: State = Entry-11 CARD #2 LOGGING TEXT [02] 0925 ALO: Searching priority group 5 CARD #2 LOGGING TEXT [02] 0926 ALO: Sat ID 1, GES ID 68 not found in blacklist CARD #2 LOGGING TEXT [02] 0927 ALO: Numbe
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal 17:06:35 #2 DEF456 E5 start 400110 14.00 dBW CT SP ocean region registration 41.5 C 0 dB Hz 17:06:35 #1 ABC123 E4 start 400110 14.00 dBW CT SP ocean region registration 41.5 C 0 dB Hz CARD #2 LOGGING TEXT [34] 1004 DspMsg: P-status at t = 210 (fr = 1, sf = 1, uw 1) CARD #2 LOGGING TEXT [34] 1005 DspMsg: P-ch SF lock at t = 210 17:06:36 #2 DEF456 E5 start 400110 14.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal (c) On-Air Voice/Data Call Verification Once the system has logged on, place a test voice and/or data call. Refer to "System Operation" on page 2-1 for detailed call procedures. Verification of all aircraft communication functions is recommended. Record the test call result on "Installation Checklist" on page E-1.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal 45D0'0.0"N 75D0'0.2"W PT 0.0D RL 0.0D HD 0.0D TK 0.0D 0 knots 0 ft 17:12:39 dop 0 ppb az 112.2 deg el 12.2 deg AORE ant gain 12.0 (sbd) CHAN #1: C/No=51.4 dB Hz sig=-31.4 dB 41.5 C no call beam=4 CHAN #2: C/No=51.5 dB Hz sig=-32.6 dB 41.5 C no call beam=5 CHAN #3: C/No=48.9 dB Hz sig=-26.1 dB 40.0 C log on beam=4 CHAN #4: C/No= 0.0 dB Hz sig= -0.0 dB 40.5 C no call beam=4 45D0'0.0"N 75D0'0.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal (a) Preparation • Perform all previous tests and document the results before proceeding. • As directed in previous tests, connect a computer to the maintenance port and use the Level 2, maint password to access the HSD-440 terminal MPU. • Power up all avionics and align the IRS. • Taxi or tow the aircraft to an unobstructed, line-of-sight location where a complete 360° rotation is possible.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal • F. Voice/data calls—in flight: Place any combination of voice and/or data calls during flight. The flight pattern may include "standard rate of turn," figure 8, or circles. Note any voice or data anomalies. Software Load Procedures EMS SATCOM may occasionally release new software for the HSD-440 terminal.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal 10. Type the COM port connected to the HSD-440 terminal, and then press ENTER. The EMS Loader prompts you to type a filename. 11. Type config.hex, and then press ENTER. The prompt asks if this is RF control software for TAL2 (channel card 1) or TAL4 (channel card 2). 12. To choose the default, N (No), press ENTER. The EMS Loader will continue to prompt for the next filename. 13.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal 4. Save ADT_LOAD.exe to the same folder on your computer that contains the software files. It is recommended that you create a folder named HSD Load in the root directory and save the load program file and the software files to this folder. 5. Apply power to the HSD-440 terminal. 6. Close all other applications running on the computer.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal 5. Apply power to the HSD-440 terminal. 6. Close all other applications running on the computer. The load program will not execute successfully if other programs are using the COM port. 7. In the HSD Load folder, double-click ADT_LOAD.exe to launch the load application. The EMS Loader opens in a DOS window, displays the Load Target menu, and prompts you to select a target for the software. 8.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal 6. To display the versions of software loaded onto the HSD-440 terminal, press V. A list of firmware versions appears similar to the example provided below (actual versions will differ depending on the software installed on the terminal). FIRMWARE VERSIONS: KERNEL: APPLICATION: CHANNEL CARD #1: CHANNEL CARD #2: DATA I/O CARD: V1.4 -- Wed Feb 21 08:58:08 2007 V11.9 -- Wed Mar 28 10:07:24 2007 4.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal (1) Non-specific Complaints When troubleshooting terminals with non-specific complaints, complete all system verification and functional tests starting on page 4–23. Document whether the terminal passes or fails each test. If the terminal passes all tests and no fault is discovered, all associated equipment and aircraft wiring should be tested.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal 10:45:14 #1 ABC123 E5 start 400110 14.00 dBW 32.0 C 54 dB Hz 10:45:15 #2 ABC456 E5 start 400110 14.00 dBW 32.0 C 55 dB Hz 10:45:19 #1 ABC123 E5 stop xxxx ORR FAIL CT SP ocean region registration CT SP ocean region registration 32.0 C 54 dB Hz Figure 4-24 Failed OR Registration 15:14:08 dop 0 ppb az 112.2 deg el 12.2 deg AORE ant gain 12.0 (p/t) CHAN #1: C/No=51.8 dB Hz sig=-32.2 dB 42.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal \ FORWARD ID TABLE -- VERSION 1 **** strapping identifies forward id ffffff -- not in table **** **** eeprom forward id 000000 not in table ***** 7.6 SECONDS: EEPROM FORCES STAND-ALONE MODE time 18.0 seconds: powering on channel card #1 time 18.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal MENU 3 FIRMWARE Vx.x L list EEPROM C clear event log F list call log O list ORT I set all LES id's N next menu G clear call log N next menu HPA ERROR CODE 1800 hit '0' for complete log S M G P list event log misc.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Log-on password entered: "Maint" MENU 1 FIRMWARE Vx.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal OMNIDIRECTIONAL MODE open loop tracking port/top active HGA LNA on port maintenance 0x00600003 port ant: status 608033 SDI=ACU gain 12 maint 600003 SDI=ACU port ant: status 608033 SDI=ACU gain 12 maint 600003 SDI=ACU port ant: status 608033 SDI=ACU gain 12 maint 600003 SDI=ACU port ant: status 608033 SDI=ACU gain 12 maint 600003 SDI=ACU port ant: status 608033 SDI=ACU gain 12 maint 600003 SDI=ACU
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table 4-22 Troubleshooting and Fault Isolation Fault Description Red LED • HPA fault remains on after powering up sequence HPA error status Maintenance Report View initial power-up display of the HSD-440 terminal MPU • reporting invalid SSM To obtain an explanation of • HPA not reporting the HPA error status word 143 status, in Menu • HPA not reporting 1, press Y maintenance word 350 • HPA mai
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table 4-22 Troubleshooting and Fault Isolation (Continued) Fault Call failure Description IRS information not available Maintenance Report Activate maintenance reports 21 and 23 Check • Check that the IRS systems are powered on and aligned. • Check that connections to the IRS systems are secured. See Figure 4-27 • Check the polarity of IRS input lines.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table 4-22 Troubleshooting and Fault Isolation (Continued) Fault Call failure (cont’d) Description ICAO ID is invalid or strapped incorrectly; FWD ID is invalid or incorrectly entered in EEPROM Maintenance Report Check Activate maintenance report 21 • The account registration process has not been completed.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table 4-22 Troubleshooting and Fault Isolation (Continued) Fault Description Logon request Terminal is not fails transmitting Maintenance Report Activate maintenance reports 21 and 23 Check • Check for defective or loose cables. • Check for antenna line-of-sight interference. • Check for HPA fault.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table 4-22 Troubleshooting and Fault Isolation (Continued) Fault Description Logon Authorization error successful, but (fault code 12C4) fails to complete call Maintenance Report Check Activate reports • Contact your service provider to verify 21 and 23 that the FWD ID is activated. See Figure 4-24 • Check that the FWD ID is entered correctly.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table 4-22 Troubleshooting and Fault Isolation (Continued) Fault Calls do not complete and connection is not established Description Channel Congestion (fault code 1851) Maintenance Report Check Activate reports • Wait five minutes and try the call 21 and 23 again. • Contact the LES to verify congestion. To contact the LES operator, dial 33 #.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal D. Fault Isolation and Diagnostic Procedures This section provides basic information required for technical personnel to isolate faults in HSD-440 terminals. Where needed, refer to other sections of this manual (which contain important information to aid in understanding the function of the terminal) for additional information.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal 9. To display the software versions of the system, press V. 10. Make a call from the system or execute the procedure or sequence that causes the call failure. Make a note of the call progress. For example: Did you get a dial tone? Was the call successful? 11. If applicable, attempt calls from the remaining channel. 12.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Blank Page 23-15-30 4-58 24 JUN 09
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal MAINTENANCE AND REPAIR This section provides maintenance and repair information for the HSD-440 terminal, including the following sections: 1. • Maintenance • Repair • Instructions for Continued Airworthiness Maintenance The HSD-440 terminal does not require routine maintenance. 2.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal (1) Warranty Returns Equipment that qualifies for warranty repair can be returned to EMS SATCOM for repair or replacement at our discretion. The customer shall pay the shipping costs to EMS SATCOM and EMS SATCOM will pay for the shipping costs to return the repaired/replaced terminal to the customer.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal 5. Write the RMA number on the outside of the shipping container and on all shipping documents, enclose a copy in the box, and send your prepaid shipment to: EMS SATCOM (867480857) 400 Maple Grove Road Ottawa, Ontario, CANADA K2V 1B8 RMA #: ___________ ATTN: Repair & Overhaul Tel: 613 591-6040 extension 1214 Fax: 613 591-8951 Email: rmareturns@emssatcom.com 6.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal minimum equipment list (MEL)]. • HSD-440 terminals are not field-repairable. All terminals must be returned to the EMS SATCOM factory or authorized repair centers for repair. • Repaired terminals must be re-installed on the aircraft in accordance with the instructions provided in this manual.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal APPENDIX A: INMARSAT SATELLITE BEAM COVERAGE Inmarsat operates strategically placed geostationary satellites called I-3 and I-4. I-3 satellites provide access to services such as Swift64 and Aero H/H+, and I-4 satellites provide access to SBB services. Each I-3 satellite is located over and named after an OR.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Figure A-2 Inmarsat I3 Satellite Beam Coverage—Composite Map 23-15-30 A-2 24 JUN 09
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Figure A-3 Inmarsat I-3 Satellite Beam Coverage—OR Maps At the time of publishing, three I-4 satellites are in service: Americas, EMEA and Asia-Pacific. Figure A-4 shows the area that is covered by the I-4 satellites.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Figure A-4 I-4 Satellite Coverage Map 23-15-30 A-4 24 JUN 09
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal APPENDIX B: TROUBLESHOOTING CHECKLIST Before performing the detailed testing and troubleshooting procedures provided in this manual, read the following Troubleshooting Checklist. Use the Troubleshooting Checklist to make sure that you have not missed any key steps in the HSD-440 terminal setup. 1.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal • Make sure that the terminal is installed with the correct power source. • Verify that all external user and networking devices (for example: TAs, routers, fax, telephones, computers) are connected and configured properly. 5.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal APPENDIX C: RJ45 CABLE TERMINATION DETAILS Figure C-1 RJ45 Cable Termination Details 23-15-30 C-1 24 JUN 09
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Blank Page 23-15-30 C-2 24 JUN 09
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal APPENDIX D: INSTALLATION PLANNING CHECKLIST Installation Planning Steps 1.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Installation Planning Steps Antenna Multi-Control BITE A/B HPA Mute A/B Power ISDN: ISDN-1 Wire one ISDN line to the ISDN port. Ethernet: Wire both Ethernet ports for SBB Ethernet-1 Ethernet-2 Wire both Ethernet ports to deploy 2 separate networks Inertial Navigation System (INS) Analog Tip/Ring (POTS) CEPT-E1, Future PBX applications (optional) 4.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal APPENDIX E: INSTALLATION CHECKLIST Aircraft Identification: HSD-440 Terminal Model No.: HSD-440 Terminal Install. Mode: HSD-440 Terminal Serial No.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Section Parameter Config.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal HSD-440 terminal Heading Antenna Antenna (Deg) Selected Azimuth CH 1 CH 2 CH 3 CH 4 C/No Signal C/No Signal C/No Signal C/No Signal 15 30 45 60 75 90 105 Operational Test 120 135 150 165 180 195 210 225 240 255 270 285 300 315 330 345 360 23-15-30 E-3 24 JUN 09
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Blank Page 23-15-30 E-4 24 JUN 09
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal APPENDIX F: ACARS/CMU MESSAGES The ACARS/CMU communicates with the HSD-440 terminal using two types of communications: Broadcast messages and Bit Oriented Protocol (BOP) messages. Both types of communication are supported at the same time. This section includes descriptions of the messages that the ACARS/CMU will transmit to the HSD-440 terminal and receive from the HSD-440 terminal.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table F-1 ACARS/CMU Update Rates for Different Devices (Continued) CMU Input Port Activity Label Minimum Update Rate (Hz) SDU 2 270 1 OOOI 3 Aircraft specific 1 OOOI 4 Aircraft specific 1 OOOI 5 Aircraft specific 1 OOOI 6 Aircraft specific 1 VDR 1 270 1 VDR 2 270 1 VDR 3 270 1 XPDR/ICAO 1 275 1 XPDR/ICAO 2 275 1 FMC HS 1 270 1 FMC HS 2 270 1 EFB-1 172 1 EF
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table F-2 Status Word 1 Differences (Continued) Bit Label 22-25 276 26 Meaning HF Status (HFDL Installed and HFDL Failed) Determines whether an ACARS or CMU is installed; ACARS = 1, CMU = 0 The ACARS/CMU transmits its position in the cockpit to the HSD-440 terminal using bits 9 and 10, as shown in Table F-3.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal 5. Understanding FWD ID Address Word One and Two; Labels 220 and 221 Each ACARS/CMU transmits the same 24 bit FWD ID address to the HSD-440 terminal. Table F-5 shows the labels and their bit positions.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table F-7 Time Clock Date Word Format (Continued) Bit Position(s) Label Description 18–15 Tens of years 4 Bit BCD for tens of years 0–9 14–11 years 3 Bit BCD for years 0–9 10–9 SDI See Table F-3 8–1 Octal Label 260 (b) Understanding Messages Received from the HSD-440 Terminal The HSD-440 terminal transmits the following identification and status words to all ACARS/CMUs.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal 1. Understanding System Identification Label 172 The HSD-440 terminal transmits system identification label 172 (SAL 307) if it is a single HSD-440 terminal that should be identified as SDU 1, as per ARINC 741 and ARINC 758. If the HSD-440 terminal should be identified as SDU 2, it transmits label 172 (SAL 173). You can find the SDU identity information in the ORT.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table F-9 Status Word 1 Bits (Continued) Bit(s) 15 Description If Set Message Alert with Chime • Refer to MCDU messages for timely information • Terminal should clear this bit once positive pilot response has been detected Message Alert without Chime • Refer to MCDU messages for routine information • Terminal should clear this bit once positive pilot response has been detected 17 Not
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table F-9 Status Word 1 Bits (Continued) Bit(s) Description 29 If Set Data • No active ACARS/CMU is available at the SDU, or the active ACARS/CMU does not respond with a Loop Word in response to a Test Word • This bit being set can be caused by the following: • • Bus inactivity on all ACARS/CMU inputs • Bus activity, but no declared active ACARS/CMU Bit may be used to set a cockpit a
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table F-10 Join/Leave Word Bits (Continued) Bits Defines Bits 25–23 Inmarsat Service: • Aero L 000 • Aero I 001 • Aero H 010 • Aero H+ 011 Bits 28–26 Not used; padded with zeros Bit 29 Data link from the AES to the GES: Bits 31–30 • Available (a Join message; Bit = 1) • Not Available (a Leave message; Bit = 0) • Identified by the GES ID and Satellite ID fields • CMU uses thi
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table F-12 Fault Summary Word 2 Bits Bits 29–11 Use Report systems as inactive or OK 13, 14, 15, 16 , 17, 21, and 24 Report that no bus activity is detected by the HSD-440 terminal ARINC Characteristic 741 describes the word format of this label.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table F-14 Variables of Low-Speed BOP—Version 1 (Continued) Time Timer or Min Max Design Goal Notes Reference Value Value for Source or Sink Description T6 Time of random timer to resolve RTS conflicts 50 ms 500 ms Goal for Source 3 2.5.81 T7 Increment of time T6 10 ms 100 ms Goal for Source 3 2.5.81 T8 ACK/NAK/SYN send time 0 ms 200 ms Goal for Sink 2.5.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table F-15 Variables of High-Speed BOP—Version 1 (Continued) Time Timer or Min Max Design Goal Notes Reference Value Value for Source or Sink Description T6 Time of random timer to resolve RTS conflicts 50 ms 500 ms Goal for Source 3 2.5.81 T7 Increment of time T6 10 ms 100 ms Goal for Source 3 2.5.81 T8 ACK/NAK/SYN send time 0 ms 200 ms Goal for Sink 2.5.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table F-16 BOP Option Defaults (Continued) Option Value O7 -- O8 Yes Notes Spare Use of SOLO word (TEST/LOOP) O9 -- Spare O10 Yes Destination code in RTS/CTS /NCTS/BUSY Used O11 Yes Bit-Protocol verification O12 No Use subsystem SAL from ALO word (b) Understanding LDUs and File Size BOP messages use Link Data Units (LDUs) encoded in binary octets to transmit data.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal 1. Understanding SALs The HSD-440 terminal sends LDUs by point to point by using a label field to carry the destination SAL; therefore, each LDU that the HSD-440 terminal sends is prefixed by the SAL for the ACARS/CMU, SAL 304. The SAL for the HSD-440 terminal is 307 (if designated SDU 1) or 173 (if designated SDU 2). See ARINC 429, Part 1, attachment 1-1 for a complete list of all SALs. 2.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table F-19 Word Types 31 30 29 WORD TYPE 0 0 0 Full Binary Data Word 0 0 1 Partial Binary Data Word 0 1 0 Start of Frame—Version 3 0 1 1 End of Frame—Version 3 1 0 0 Protocol Word 1 0 1 Solo Word 1 1 0 Start Of Transmission—Version 1 1 1 1 End Of Transmission—Version 1 1. Understanding the Full Binary Data Word This word shall transmit 5 nibbles of data.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table F-20 Protocol Words and Uses (Continued) Protocol word Uses ACK (acknowledgement) If the HSD-440 terminal transfers each word within the designated time and with odd parity, correct word count, and verified CRC. The LDU is either next, first, or a duplicate. Then the HSD-440 terminal sends an ACK.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal The solo word also performs test and loop back functions to test the integrity of the ARINC 429 bus interconnection between the HSD-440 terminal and the ACARS/CMU. The HSD-440 terminal can send a 16 bit loop test pattern word (TEST) on the ARINC 429 TX bus. The ACARS/CMU then responds with the identical loop test pattern word (LOOP) on the ARINC 429 RX bus.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Blank Page 23-15-30 F-18 24 JUN 09
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal APPENDIX G: INTERNATIONAL ACCESS AND COUNTRY CODES Table G-1 shows a list of countries with their associated country codes and international access codes.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table G-1 International Access and Country Codes (Continued) Country Country Code International Access Code Cameroon 237 00 Canada 1 011 Cape Verde 238 0 Cayman Islands +1 (345) 011 Central African Republic 236 19 Chad 235 15 Chile 56 00 China 86 00 Colombia 57 009 Comoros 269 00 Congo (Brazzaville) 242 00 Congo (Kinshasa, formerly Zaire) 243 00 Cook Islands
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table G-1 International Access and Country Codes (Continued) Country Country Code International Access Code French Antilles 590 00 French Guiana 594 00 French Polynesia 689 00 Gabon 241 00 Gambia 220 00 Germany 49 00 Ghana 233 00 Gibraltar 350 00 Greece 30 00 Greenland 299 009 Grenada +1 (473) 011 Guam +1 (671) 011 Guatemala 502 00 Guinea 224 00 Guinea-
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table G-1 International Access and Country Codes (Continued) Country Country Code International Access Code Latvia 371 810 Lebanon 961 00 Lesotho 266 00 Liberia 231 00 Libya 218 00 Liechtenstein 423 00 Lithuania 370 00 Luxembourg 352 00 Macao 853 00 Macedonia 389 00 Madagascar 261 16 Malawi 265 101 Malaysia 60 00 Maldives 960 00 Mali 223 00 Malta 35
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table G-1 International Access and Country Codes (Continued) Country Country Code International Access Code Niger 227 00 Nigeria 234 009 Niue Island 683 00 North Korea 850 00 Northern Mariana Islands (Commonwealth of) +1 (670) 011 Norway 47 095 Oman 968 00 Pakistan 92 00 Palau 680 011 Palestine 970 00 Panama 507 00 Papua New Guinea 675 05 Paraguay 595 002
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table G-1 International Access and Country Codes (Continued) Country Country Code International Access Code Spain 34 00 Sri Lanka 94 00 St Helena and Tristan da Cunha 290 00 St Kitts +1 (869) 011 St Lucia +1 (758) 011 St Pierre and Miquelon 508 00 St Vincent +1 (784) 011 Sudan 249 00 Suriname 597 002 Swaziland 268 00 Sweden 46 00 Switzerland 41 00 Syria 963
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table G-1 International Access and Country Codes (Continued) Country Country Code International Access Code Vatican City +39, +379 00 Venezuela 58 00 Vietnam 84 00 Wallis and Futuna 681 19 Yemen 967 00 Yugoslavia (+38 discontinued) 99 Zambia 260 00 Zimbabwe 263 110 23-15-30 G-7 24 JUN 09
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Blank Page 23-15-30 G-8 24 JUN 09
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal APPENDIX H: INMARSAT CAUSE CODES Table H-1 defines the maintenance port menu fault codes of the HSD-440 terminal.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table H-1 Inmarsat Cause Code Definitions (Continued) Inmarsat Cause Code Code Definition 1662 LES long term blockage of SCPC MES 1790 Call cleared, failure credit card validation process 1791 Call cleared, failure authentication process 1811 NCS MES ID busy 1812 NCS MES ID busy IPDS 1841 Call cleared, NCS initiated preemption for incoming Pri.
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table H-1 Inmarsat Cause Code Definitions (Continued) Inmarsat Cause Code Code Definition 2052 Call failed, LES selected is barred 2053 Call failed, number dialed must be in a phonebook 2053 Call failed, terminal can only be used with a valid SIM 2055 Call failed, user not logged in 2056 Call failed, user not logged in to SIM 2057 Call failed, LES is not in SIM allowed list 2058 Cal
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table H-1 Inmarsat Cause Code Definitions (Continued) Inmarsat Cause Code Code Definition 8001 ACSE Top Of Find BB 8002 ACSE Top Of Process BB 8010 ACSE Finding Primary NCS Long 8011 ACSE Finding Secondary NCS Short 8012 ACSE Finding Primary Standalone Short 8013 ACSE Finding Primary NCS Short 8014 ACSE Finding Primary Standalone Long 8018 ACSE Finding Secondary Standalone Short
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table H-1 Inmarsat Cause Code Definitions (Continued) Inmarsat Cause Code Code Definition 8310 ACSE ORR Query Begin 8311 ACSE ORR Query Burst 8312 ACSE ORR Query Successful 8313 ACSE ORR Query Failed 8400 ACSE Fixed Begin 8401 ACSE Fixed MESRP 8402 ACSE Fixed Call Type Set 8410 ACSE Fixed Tune NCSA 8411 ACSE Fixed Channel Assignment 8420 ACSE Fixed Clearing Call 8421 ACSE Fi
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table H-1 Inmarsat Cause Code Definitions (Continued) Inmarsat Cause Code Code Definition 8901 ACSE Successful Logoff 8902 ACSE No ORR Logoff 9000 ACSE accepts call 9003 ACSE accepted 9004 ACSE rejected 9020 ACSE call waiting 9021 ACSE idle selective clear 9022 ACSE TDM not found 9080 ACSE rejected fixed call due to invalid NSR 9081 ACSE In MRSi 9082 ACSE sounder turned on
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table H-1 Inmarsat Cause Code Definitions (Continued) Inmarsat Cause Code Code Definition 9130 Peripheral STU enabled 9131 Peripheral STU disabled 9200 MSG T_AM received 9201 MSG A_AM received 9202 MSG T_HA received 9203 MMI normal 9204 MMI inert 9205 MMI programming 9206 MMI reboot 9207 MMI powerdown 9208 MMI accepted 9209 MMI rejected 400000 CT SP bad 400000 No call
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table H-1 Inmarsat Cause Code Definitions (Continued) Inmarsat Cause Code Code Definition 400902 CT SP ODU status DDS 400910 CT SP prod test 400911 CT SP prod test ODU 401000 CT SP clear spot beam 800124 Mobile aero 64k speech 800404 Mobile data 800504 Mobile facsimile 800606 Mobile 64k UDI 800607 Mobile 56k UDI 800610 Mobile 64k audio 3k1 800622 Mobile aero 64k UDI 800623
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table H-1 Inmarsat Cause Code Definitions (Continued) Inmarsat Cause Code Code Definition 12D1 Call failed, Spot-beam data invalid 12D2 Call failed, invalid scrambling vector 15A1 Call failed, MES not authorized at this LES 15A2 Call failed, service not authorized at this LES 15A3 Call cleared, credit card not authorized 15A4 Call cleared, authentication reply invalid 15A5 Call fail
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table H-1 Inmarsat Cause Code Definitions (Continued) Inmarsat Cause Code Code Definition 1F11 Call failed, terrestrial party busy 1F21 Call failed, LES time-out (no answer) 1F61 Call failed, terrestrial circuit failure (call attempted during ORR) 1F62 Call failed, early clear by terrestrial circuit 2F00 LES int reject lack of MES RESP response 2F01 LES int reject lack of MES ARN resp
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table H-1 Inmarsat Cause Code Definitions (Continued) Inmarsat Cause Code Code Definition B025 MOD invalid slot no B028 MOD cannot Tx Su while tuning B030 MOD channel out of range B032 MOD cannot tune while Tx B033 MOD tuning in progress B040 MOD error watchdog B100 DEMOD error, general B101 DEMOD error, tune failed B102 DEMOD error, mode failed B110 DEMOD invalid mode B130
EMS SATCOM SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-440 High-speed Data Terminal Table H-1 Inmarsat Cause Code Definitions (Continued) Inmarsat Cause Code Code Definition B329 ODU error alarm timeout B330 ODU error alarm timeout no trip B400 Internal temperature of terminal too high, turn off for 10 minutes B401 Internal temperature sensor failed B410 Mod error, handshake failure, power down/up and try again B500 Battery charging communication failure B501 Power