SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
ARINC 781-500 SDU and SCM
The aircraft has to be outside the hangar and far away from the hangars and towers in order to
obtain good results.
The aircraft must be facing due north in the northern hemisphere, and due south in the south-
ern hemisphere.
C. PIM Test
To run the PIM test
, you must be in maintenance mode.You can only access the TCP maintena
nce
menus when the plane is on
the ground and classic services are logged off.
To start the PIM test:
(a) In the TCP CONFIG 1/5 menu, type the protection level code in the scratchpad, and
press the button next to PROT LEVEL CODE.
NOTE: Contact RC Product Support for the PROT level code.
The SATCOM Maintenance Entry page app
ears.
(b) To enter maintenance mode, press the
button next to CONFIRM.
The MAINTENANCE MENU appears.
(c) To start the PIM test, press the button next to INTERMOD TEST.
(d) Press the button next to RUN in order to initiate the PIM test.
The PIM test starts. The test takes about 5 minutes.