Table 2-2 describes the information available in the SBB menu.
Table 2-2. SBB Menu
Label Description
Status The status of the SBB channel. Possible values are:
• HSR NOT READY—high stability oscillator is warming
• USIM WARMING—USIM is warming
• NOT READY—channel card has not yet started
registration, and may be waiting on the Classic card
• ATTACHING—satellite identified and attach has begun
• CS ATTACH—attach complete, circuit-switch granted
• PS ATTACH—attach complete, packet-switch granted
• CSPS ATTACH—attach complete, circuit-switch and
packet-switch granted
• ATTACH-FAIL— attach failed, with the 3GPP cause code
• NOT READY—selected satellite does not support SBB
• DISABLED—selected SBB service is not configured in the
operational mode
Satellite The selected ocean region.
Activity The activity status of the SBB service. Possible values are:
• CS CONNECT—Circuit Switched services in use
• PS CONNECT—Packet Switched services in use
• CSPS CONNECT—Circuit Switched services and Packet
Switched services in use
• NONE —No services in use
Signal The current signal quality.
EIRP The EIRP setting of the channel.
Beam ID The current beam ID for the service.
Elevation The computed elevation angle for the antenna pointing
vector.