User's Manual
Table Of Contents
- toc
- TRANSMITTAL INFORMATION
- INTRODUCTION
- 1. How to Use This Manual (TASK 23-15-30-99F-801- a 01)
- A. General (Subtask 23-15-30-99F-001- a 01)
- B. Observance of Manual Instructions (Subtask 23-15-30-99F-002-
- C. Symbols (Subtask 23-15-30-99F-003- a 01)
- D. Units of Measure (Subtask 23-15-30-99F-004- a 01)
- E. Illustration (Subtask 23-15-30-99F-005- a 01)
- F. Application of Maintenance Task Oriented Support System (MTOS
- 2. Customer Support (TASK 23-15-30-99F-802- a 01)
- 3. References (TASK 23-15-30-99F-803- a 01)
- 4. Acronyms and Abbreviations (TASK 23-15-30-99F-804- a 01)
- 5. Process Verification (TASK 23-15-30-99F-805- a 01)
- 1. How to Use This Manual (TASK 23-15-30-99F-801- a 01)
- DESCRIPTION AND OPERATION
- TESTING AND FAULT ISOLATION
- 1. Planning Data (TASK 23-15-30-99C-801- a 01)
- 2. Procedure (TASK 23-15-30-700-801- a 01)
- A. Job Setup (Subtask 23-15-30-810-001- a 01)
- B. BITE (Subtask 23-15-30-810-002- a 01)
- C. LEDs (Subtask 23-15-30-810-003- a 01)
- D. Self-Test (Subtask 23-15-30-810-004- a 01)
- E. Unit Software Load Procedure (Subtask 23-15-30-810-005- a 01)
- F. Fault Isolation (Subtask 23-15-30-810-006- a 01)
- G. Job Close-up (Subtask 23-15-30-810-007- a 01)
- CLEANING
- INSPECTION/CHECK
- 1. Planning Data (TASK 23-15-30-99C-803- a 01)
- 2. Procedure (TASK 23-15-30-210-801- a 01)
- A. Job Setup (Subtask 23-15-30-210-001- a 01)
- B. General Inspection/Check Procedure of the A350 SDU and SCM (S
- C. Instructions for Continued Airworthiness, FAR 25.1529 (Subtas
- D. Inspection/Check Schedule (Subtask 23-15-30-210-004- a 01)
- E. Unscheduled Maintenance (Subtask 23-15-30-210-005- a 01)
- F. Repair Requirements (Subtask 23-15-30-210-006- a 01)
- G. Job Close-up (Subtask 23-15-30-210-007- a 01)
- REPAIR
- FITS AND CLEARANCES
- SPECIAL TOOLS, FIXTURES, EQUIPMENT, AND CONSUMABLES
- REMOVAL
- INSTALLATION
- 1. Planning Data (TASK 23-15-30-99C-808- a 01)
- 2. Procedure (TASK 23-15-30-400-801- a 01)
- A. Job Setup (Subtask 23-15-30-400-001- a 01)
- B. Installation Data (Subtask 23-15-30-400-002- a 01)
- C. Unpacking and Inspecting Equipment (Subtask 23-15-30-400-003-
- D. Customer Acceptance Procedure (Subtask 23-15-30-400-004- a 01
- E. Installation Procedure (Subtask 23-15-30-400-005- a 01)
- F. Test (Subtask 23-15-30-400-006- a 01)
- G. Job Close-up (Subtask 23-15-30-400-007- a 01)
- STORAGE (INCLUDING TRANSPORTATION)
- REWORK
- APPENDIX A (RMA)
- tables
- Table 1. Applicable Components
- Table 2. Revision History
- Table 3. MTOSS Function Code Definitions
- Table 4. Verification Data
- Table 5. SDU Leading Particulars
- Table 6. SCM Leading Particulars
- Table 7. Equipment Description
- Table 8. SDU Rear Connector Pin Deviations
- Table 9. SCM D-Type Connector Pin Assignment
- Table 10. SDU Functional Interfaces
- Table 11. Special Tools, Fixtures, and Equipment
- Table 12. Consumables
- Table 13. LED Status Indicators Table
- Table 14. Special Tools, Fixtures, and Equipment
- Table 15. Consumables
- Table 16. Special Tools, Fixtures, and Equipment
- Table 17. Consumables
- Table 18. Special Tools, Fixtures, and Equipment
- Table 19. Consumables
- Table 20. Fits and Clearances
- Table 21. Thread Size and Torque Data
- Table 22. Final Torque Data
- Table 23. Special Tools, Fixtures, and Equipment
- Table 24. Consumable Materials
- Table 25. Special Tools, Fixtures, and Equipment
- Table 26. Consumable Materials
- Table 27. Special Tools, Fixtures, and Equipment
- Table 28. Consumables
ABBREVIATED COMPONENT MAINTENANCE MANUAL
1458-A-1101 / 1458-A-1300
(b) The major interfaces of the SDU are shown in Table 10.
Table 10. SDU Functional Interfaces
Interface Description Type
HGA (x1) HGA/DLNA A429 bus
HPA (x1) HPA A429 bus
RMP (x3) RMU (for Control and Display) A429 bus
AFDX (x2) AFDX AFDX bus
ADIRU virtual links AFDX VL
LGERS virtual links AFDX VL
CMS virtual links AFDX VL
DLCS virtual links AFDX VL
FWS virtual links AFDX VL
DFDRS virtual links AFDX VL
SPP virtual links AFDX VL
SCM (x1) SCM RS422
SCM 12V power SCM power Power
SIS (x1) SIS I2C
Servicing Front panel accessible service port for data log retrieval Ethernet
Miscellaneous ARINC discrete input, outputs and configuration straps Discretes
(c) The frequency of operation is as follows:
• Receive band - 1525.0 to 1559.0 MHz
• Transmit band - 1626.5 to 1660.5 MHz.
(3) Refer to Figure 10 (GRAPHIC 23-15-30-99B-810-A01) for the System Interconnection Drawing.
EFFECTIVITY
ALL
23-15-30
Page 43 of 70
5 Oct 2012
© Honeywell International Inc. Do not copy without express permission of Honeywell.
Interim DRAFT for FCC Approval Purposes
Do Not Use for Maintenance
10-Feb-2013